Safety data sheet
Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revised on / Version: 15.12.2014 / 0002
Replaces revision of / Version: 17.01.2013 / 0001
Valid from: 15.12.2014
PDF print date: 16.12.2014
26035 TESLANOL WR Walzenreiniger 1000 ml
7.1.1 General recommendations
Ensure good ventilation.
Avoid inhalation of the vapours.
If applicable, suction measures at the workstation or on the processing machine necessary.
Avoid contact with eyes or skin.
Keep away from sources of ignition - Do not smoke.
Take measures against electrostatic charging, if appropriate.
Eating, drinking, smoking, as well as food-storage, is prohibited in work-room.
Observe directions on label and instructions for use.
Use working methods according to operating instructions.
7.1.2 Notes on general hygiene measures at the workplace
General hygiene measures for the handling of chemicals are applicable.
Wash hands before breaks and at end of work.
Keep away from food, drink and animal feedingstuffs.
Remove contaminated clothing and protective equipment before entering areas in which food is consumed.
7.2 Conditions for safe storage, including any incompatibilities
Keep out of access to unauthorised individuals.
Not to be stored in gangways or stair wells.
Store product closed and only in original packing.
Do not store with flammable or self-igniting materials.
Observe special storage conditions (in Germany, e.g., in accordance with the regulations in the "Betriebssicherheitsverordnung").
Under all circumstances prevent penetration into the soil.
Store in a dry place.
Store cool
7.3 Specific end use(s)
No information available at present.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Workplace exposure limit (WEL) of the total hydrocarbon solvent content of the mixture (RCP method according to EH40):
1200 mg/m3
Chemical Name
Hydrocarbons, C7-C9, n-alkanes, isoalkanes, cyclics
Content %:70-
90
WEL-TWA: 1200 mg/m3 WEL-STEL: --- ---
BMGV: --- Other information: ---
Chemical Name
Propan-2-ol
Content %:10-
<15
WEL-TWA: 400 ppm (999 mg/m3) WEL-STEL: 500 ppm (1250 mg/m3) ---
BMGV: --- Other information: ---
Chemical Name
Methyl acetate
Content %:1-10
WEL-TWA: 200 ppm (616 mg/m3) WEL-STEL: 250 ppm (770 mg/m3) ---
BMGV: --- Other information: ---
Chemical Name
Xylene (mixture of isomers)
Content %:1-5
WEL-TWA: 50 ppm (220 mg/m3) (WEL), 50 ppm
(221 mg/m3) (EU)
WEL-STEL: 100 ppm (441 mg/m3 (WEL), 100
ppm (442 mg/m3) (EU)
---
BMGV: 650 mmol methyl hippuric acid/mol creatinine in urine, post shift
(Xylene, o-, m-, p- or mixed isomers) (BMGV)
Other information: Sk (WEL)
WEL-TWA = Workplace Exposure Limit - Long-term exposure limit (8-hour TWA (= time weighted average) reference period)
EH40. AGW = "Arbeitsplatzgrenzwert" (workplace limit value, Germany). | WEL-STEL = Workplace Exposure Limit - Short-term
exposure limit (15-minute reference period). | BMGV = Biological monitoring guidance value EH40. BGW = "Biologischer Grenzwert"
(biological limit value, Germany) | Other information: Sen = Capable of causing occupational asthma. Sk = Can be absorbed through
skin. Carc = Capable of causing cancer and/or heritable genetic damage.
** = The exposure limit for this substance is repealed through the TRGS 900 (Germany) of January 2006 with the goal of revision.
Propan-2-ol
Page 5 of 16