Safety data sheet
Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revised on / Version: 15.12.2014 / 0003
Replaces revision of / Version: 17.10.2012 / 0002
Valid from: 15.12.2014
PDF print date: 16.12.2014
26027 TESLANOL T7 Isolier-Schutzlack 200 ml
26028 TESLANOL T7 Isolier-Schutzlack 400 ml
Hydrocarbons, C7-C9, n-alkanes, isoalkanes, cyclics
Area of application Exposure route /
Environmental
compartment
Effect on health Descripto
r
Value Unit Note
Workers / employees Human - dermal Long term, systemic
effects
DNEL 773 mg/kg
bw/d
Workers / employees Human - inhalation Long term, systemic
effects
DNEL 2035 mg/m3
Consumer Human - dermal Long term, systemic
effects
DNEL 699 mg/kg
bw/d
Consumer Human - inhalation Long term, systemic
effects
DNEL 608 mg/m3
Human - oral Long term, systemic
effects
DNEL 699 mg/kg
bw/d
8.2 Exposure controls
8.2.1 Appropriate engineering controls
Ensure good ventilation. This can be achieved by local suction or general air extraction.
If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn.
Applies only if maximum permissible exposure values are listed here.
8.2.2 Individual protection measures, such as personal protective equipment
General hygiene measures for the handling of chemicals are applicable.
Wash hands before breaks and at end of work.
Keep away from food, drink and animal feedingstuffs.
Remove contaminated clothing and protective equipment before entering areas in which food is consumed.
Eye/face protection:
With danger of contact with eyes.
Tight fitting protective goggles with side protection (EN 166).
Skin protection - Hand protection:
Solvent resistant protective gloves (EN 374).
Recommended
Protective nitrile gloves (EN 374)
Minimum layer thickness in mm:
0,4
Permeation time (penetration time) in minutes:
> 480
Protective hand cream recommended.
Skin protection - Other:
Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments)
Respiratory protection:
Normally not necessary.
If OES or MEL is exceeded.
Filter A2 P2 (EN 14387), code colour brown, white
At high concentrations:
Respiratory protection appliance (insulation device) (e.g. EN 137 or EN 138)
Observe wearing time limitations for respiratory protection equipment.
Thermal hazards:
Not applicable
Additional information on hand protection - No tests have been performed.
In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents.
Selection of materials derived from glove manufacturer's indications.
Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account.
Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer
to manufacturer.
In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use.
The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.
Page 7 of 17