Safety data sheet

Safety data sheet according to Regulation (EC) No 1907/2006, Annex II
Revised on / Version: 15.12.2014 / 0003
Replaces revision of / Version: 11.01.2013 / 0002
Valid from: 15.12.2014
PDF print date: 16.12.2014
26002 TESLANOL D Druck-Gas-Spray 200 ml
26003 TESLANOL D Druck-Gas-Spray 400 ml
Store product closed and only in original packing.
Do not store with flammable or self-igniting materials.
Observe special storage conditions (in Germany, e.g., in accordance with the regulations in the "Betriebssicherheitsverordnung").
Observe special regulations for aerosols!
Store in a dry place.
Store cool
Keep protected from direct sunlight and temperatures over 50°C.
Only store at temperatures from 15°C to 35°C.
7.3 Specific end use(s)
No information available at present.
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Chemical Name
Butane
Content %:
WEL-TWA: 600 ppm (1450 mg/m3) WEL-STEL: 750 ppm (1810 mg/m3) ---
BMGV: --- Other information: ---
Chemical Name
Propane
Content %:
WEL-TWA: 1000 ppm (ACGIH) WEL-STEL: --- ---
BMGV: --- Other information: ---
Chemical Name
Isobutane
Content %:
WEL-TWA: 1000 ppm (ACGIH) WEL-STEL: --- ---
BMGV: --- Other information: ---
WEL-TWA = Workplace Exposure Limit - Long-term exposure limit (8-hour TWA (= time weighted average) reference period)
EH40. AGW = "Arbeitsplatzgrenzwert" (workplace limit value, Germany). | WEL-STEL = Workplace Exposure Limit - Short-term
exposure limit (15-minute reference period). | BMGV = Biological monitoring guidance value EH40. BGW = "Biologischer Grenzwert"
(biological limit value, Germany) | Other information: Sen = Capable of causing occupational asthma. Sk = Can be absorbed through
skin. Carc = Capable of causing cancer and/or heritable genetic damage.
** = The exposure limit for this substance is repealed through the TRGS 900 (Germany) of January 2006 with the goal of revision.
8.2 Exposure controls
8.2.1 Appropriate engineering controls
Ensure good ventilation. This can be achieved by local suction or general air extraction.
If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn.
Applies only if maximum permissible exposure values are listed here.
8.2.2 Individual protection measures, such as personal protective equipment
General hygiene measures for the handling of chemicals are applicable.
Wash hands before breaks and at end of work.
Keep away from food, drink and animal feedingstuffs.
Remove contaminated clothing and protective equipment before entering areas in which food is consumed.
Eye/face protection:
Normally not necessary.
Skin protection - Hand protection:
Normally not necessary.
Skin protection - Other:
Usual protective working garments
Respiratory protection:
Normally not necessary.
If OES or MEL is exceeded.
Gas mask filter AX (EN 14387), code colour brown.
At high concentrations:
Respiratory protection appliance (insulation device) (e.g. EN 137 or EN 138)
Observe wearing time limitations for respiratory protection equipment.
Thermal hazards: