Installation Guide
Table Of Contents
- About This Guide
- Overview
- Installing the IntelliVue Smart-hopping 1.4 GHz Core Access Point
- Access Point Placement Guidelines
- ITS4843D Installation Procedure
- ITS4843B and ITS4843C Installation Procedure
- Mounting the IntelliVue Smart-hopping Core AP to a Wall (Fixed Mount)
- Mounting the IntelliVue Smart-hopping Core AP to a Wall (CA Earthquake Rated)
- Mounting the IntelliVue Smart-hopping Core AP Above a Ceiling Tile
- Mounting the IntelliVue Smart-hopping Core AP Below a Ceiling Tile (Fixed Mount)
- Mounting the IntelliVue Smart-hopping Core AP Below a Ceiling Tile (Quick Release)
- Mounting the IntelliVue Smart-hopping Remote Antenna to a Wall (Fixed Mount)
- Mounting the IntelliVue Smart-hopping Remote Antenna to a Wall (CA Earthquake Rated)
- Mounting the IntelliVue Smart-hopping Remote Antenna Above a Ceiling Tile (Mounting Rails)
- Mounting the IntelliVue Smart-hopping Remote Antenna Above a Ceiling Tile (Tether Mount)
- Mounting the IntelliVue Smart-hopping Remote Antenna Below a Ceiling Tile (Fixed Mount)
- Mounting the IntelliVue Smart-hopping RA Below a Ceiling Tile (Quick Release)
- AP Configuration Information
- Access Point Startup Sequence
- Maintaining the IntelliVue Smart-hopping 1.4 GHz Core Access Point
- Index
Mounting the IntelliVue Smart-hopping Core AP to a Wall (CA Earthquake Rated)
IntelliVue Smart-hopping 1.4 GHz Access Point Installation Guide 2-11
4. Using a 5/64-inch (2 mm) Allen (i.e., hexagonal) wrench, secure the four
supplied M3 X 0.5 hex-head shoulder screws to the back of the Core AP as
shown in Figure 2-6. Torque-tighten each shoulder screw to 8-inch lbs.
5. Mount the Core AP to the wall plate by inserting the head of each shoulder
screw into the four mounting holes provided in the wall plate and then sliding
the Core AP down so that the shoulder screw heads are securely in the grooves
of the wall plate.
6. Using a Torx T10 screw driver, secure the Core AP to the wall plate by screwing
the supplied M3.5 X 0.6 T-10 Torx Head security screw into the PEM nut in the
wall plate as shown in Figure 2-7. Torque-tighten the screw to 10-inch lbs. Note
that this safety screw is used to prevent the Core AP from sliding out of the wall
plate.
Figure 2-7: Securing the Core AP to its Quick Release Wall Plate
Insert M3.5 Security Screw
through this View Port and
Tighten Using a Torx T10
Screwdriver.