Installation Guide
Table Of Contents
- About This Guide
- Overview
- Installing the IntelliVue Smart-hopping 1.4 GHz Core Access Point
- Access Point Placement Guidelines
- ITS4843D Installation Procedure
- ITS4843B and ITS4843C Installation Procedure
- Mounting the IntelliVue Smart-hopping Core AP to a Wall (Fixed Mount)
- Mounting the IntelliVue Smart-hopping Core AP to a Wall (CA Earthquake Rated)
- Mounting the IntelliVue Smart-hopping Core AP Above a Ceiling Tile
- Mounting the IntelliVue Smart-hopping Core AP Below a Ceiling Tile (Fixed Mount)
- Mounting the IntelliVue Smart-hopping Core AP Below a Ceiling Tile (Quick Release)
- Mounting the IntelliVue Smart-hopping Remote Antenna to a Wall (Fixed Mount)
- Mounting the IntelliVue Smart-hopping Remote Antenna to a Wall (CA Earthquake Rated)
- Mounting the IntelliVue Smart-hopping Remote Antenna Above a Ceiling Tile (Mounting Rails)
- Mounting the IntelliVue Smart-hopping Remote Antenna Above a Ceiling Tile (Tether Mount)
- Mounting the IntelliVue Smart-hopping Remote Antenna Below a Ceiling Tile (Fixed Mount)
- Mounting the IntelliVue Smart-hopping RA Below a Ceiling Tile (Quick Release)
- AP Configuration Information
- Access Point Startup Sequence
- Maintaining the IntelliVue Smart-hopping 1.4 GHz Core Access Point
- Index
Ordering Information
IntelliVue Smart-hopping 1.4 GHz Access Point Installation Guide 1-15
Ordering Information
Antenna Type Sleeve Dipole > 10dB over 1395MHz to 1432MHz in 50 Ohms.
LED Indicators Power and Connection LED notification on RJ-45 connector.
Electrical Installation:
Fire Safety Model ITS4846B 1.4 GHz Remote Antennas are Listed for use within "Other
Spaces Used for Environmental Air (Plenum)" per NFPA70: 2011, Article
300.22.
Note: The term "plenum" as used in Article 300.22 Section C correlates with the
use of the term "plenum" in NFPA 90A-2009, Standard for the Installation of Air-
Conditioning and Ventilating Systems, and other mechanical codes where the
plenum is used for return air purposes, as well as some other air-handling
spaces. The area above dropped ceilings is an example of plenum space.
Interface Connections:
Control Signals RJ-45 Female Socket.
Core AP 75 Ohm Coaxial Cable
Connector
One standard 75 Ohm connector is provided for the coaxial cable on which RF
and DC sense signals are carried to the Remote Antenna.
Local Antenna Connections (two) Two SMA-style connectors.
Table 1-6: Model ITS4846B 1.4 GHz RTX Remote Antenna Specifications
Specification Value
Table 1-7: IntelliVue Smart-hopping 1.4 GHz Access Point Part Numbers
Device/Option Part Number/Option Number
ITS4843B 1.4 GHz Enhanced IntelliVue Smart-hopping Access Point 989803171211
ITS4843C 1.4 GHz Enhanced IntelliVue Smart-hopping Access Point
(High power AP)
989803171211
ITS4843D Radiohead 1.4 GHz Enhanced IntelliVue Smart-hopping
Access Point (High power AP) with RTX Remote Antenna
866394
IntelliVue ITS4846A Remote Antenna 865052, 866394
IntelliVue ITS4846B 1.4 GHz RTX Remote Antenna 867151
IntelliVue Smart-hopping Mounting Options:
Above & Below Ceiling Tile-mount Option for the following:
• 989803171211
• 865052
• 866394
453564052201 or
862415/K05