Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Take
precautionary measures against static discharge. Use only non-sparking tools. Keep combustibles
(wood, paper, oil, etc.) away from spilled material.
Large Spills: Stop the flow of material, if this is without risk. Dike the spilled material, where this is
possible. Cover with plastic sheet to prevent spreading. Use a non-combustible material like
vermiculite, sand or earth to soak up the product and place into a container for later disposal.
Following product recovery, flush area with water.
Small Spills: Absorb with earth, sand or other non-combustible material and transfer to containers
for later disposal. Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination.
Never return spills to original containers for re-use. For waste disposal, see section 13 of the SDS.
Methods and materials for
containment and cleaning up
Use appropriate containment to avoid environmental contamination.
Environmental precautions
7. Handling and storage
Do not handle, store or open near an open flame, sources of heat or sources of ignition. Protect
material from direct sunlight. When using do not smoke. Explosion-proof general and local exhaust
ventilation. Minimize fire risks from flammable and combustible materials (including combustible
dust and static accumulating liquids) or dangerous reactions with incompatible materials. Handling
operations that can promote accumulation of static charges include but are not limited to: mixing,
filtering, pumping at high flow rates, splash filling, creating mists or sprays, tank and container
filling, tank cleaning, sampling, gauging, switch loading, vacuum truck operations. Take
precautionary measures against static discharges. All equipment used when handling the product
must be grounded. Use non-sparking tools and explosion-proof equipment. Avoid breathing mist or
vapor. Avoid contact with eyes. Avoid prolonged exposure. Wear appropriate personal protective
equipment.
For additional information on equipment bonding and grounding, refer to the Canadian Electrical
Code in Canada, (CSA C22.1), or the American Petroleum Institute (API) Recommended Practice
2003, "Protection Against Ignitions Arising out of Static, Lightning, and Stray Currents" or National
Fire Protection Association (NFPA) 77, "Recommended Practice on Static Electricity" or National
Fire Protection Association (NFPA) 70, "National Electrical Code".
Precautions for safe handling
Store locked up. Keep away from heat, sparks and open flame. Prevent electrostatic charge
build-up by using common bonding and grounding techniques. Eliminate sources of ignition. Avoid
spark promoters. Ground/bond container and equipment. These alone may be insufficient to
remove static electricity. Store in a cool, dry place out of direct sunlight. Store in original tightly
closed container. Store in a well-ventilated place. Keep in an area equipped with sprinklers. Store
away from incompatible materials (see Section 10 of the SDS).
Conditions for safe storage,
including any incompatibilities
8. Exposure controls/personal protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
ValueComponents Type
PEL 1900 mg/m3Ethanol (CAS 64-17-5)
1000 ppm
PEL 980 mg/m3Isopropanol (CAS 67-63-0)
400 ppm
US. ACGIH Threshold Limit Values
ValueComponents Type
STEL 1000 ppmEthanol (CAS 64-17-5)
STEL 400 ppmIsopropanol (CAS 67-63-0)
TWA 200 ppm
US. NIOSH: Pocket Guide to Chemical Hazards
ValueComponents Type
TWA 1900 mg/m3Ethanol (CAS 64-17-5)
1000 ppm
STEL 1225 mg/m3Isopropanol (CAS 67-63-0)
500 ppm
TWA 980 mg/m3
400 ppm
3 / 10