7. Turn key farther clockwise, against spring pressure, to position '2' to crank
engine; release key as soon as engine starts firing.
Note: Engine MUST be started with foot 'OFF' the accelerator pedal.
Note: Never crank the engine more than 30 seconds continuously. Allow starter
at least 2 minutes cooling time between cranking periods to avoid overheating.
8
7
1142
407
8. The amber 'Check Engine' and red 'Stop Engine' lights should come on, and
then go out after 6 - 10 seconds. If the amber 'Check Engine' light does not go
out, have the system checked out as soon as possible. If the red 'Stop Engine'
light does not go out after 6 - 10 seconds, or illuminates during operation, stop
the engine immediately.
Note: In an emergency operation situation only, the 'Stop Engine Override' switch
may be used for a short period of time to allow the vehicle to be brought to a safe
stop.