OPERATING INSTRUCTIONS
LIGHT TOWER AUXILIARY POWER:
1) One 15 amp, 125 VAC GFI receptacle is provided for auxiliary power.
2) Total auxiliary power cannot exceed main circuit breaker rating. Each lamp operating
consumes 9.5 amps of 110 volt power.
3) Before plugging in auxiliary power cords, feed them up through the trailer frame and
attach to receptacles. Close the cabinet doors to protect control panel and other compo-
nents from weather.
SHUTDOWN PROCEDURES:
1) Place all light switches into their “OFF” position.
2) Allow the engine to run for 1 to 5 minutes under no load, then turn the unit “OFF”.
Never shut the unit down while under load. The
AC generator may become damaged.
After being shut down, the lights must be allowed
to cool down before trying to restart the lights.
This cool down period can be between 10-25 min-
utes, depending on the ambient temperature.
LOWERING THE TOWER:
1) Using the upper telescoping winch, telescope the tower down to its fully retracted posi-
tion.
The boom should lower smoothly and evenly to
its lowest position. If it does not, contact a quali-
fied mechanic.
Insure the coil cord does not become entangled
with the lower tower sections.