5.5.5. Reset counters
This command will reset the counters for both presence detection and bidirectional
people traffic detection modes.
Once the sensor receives the reset command, the sensor outputs the following frames
that contain this additional information:
5.5.5.1. BPTD “Bidirectional People Traffic Mode”
“PC”
2 bytes
Counter
4 bytes
Counter IN
2 bytes
Counter OUT
2 bytes
CRC
1 byte
Where: “PC”: frame header
Counter = Counter IN - Counter OUT = 0
Counter IN: number of people passing by from Left to Right = 0
Counter OUT: number of people passing by from Right to Left = 0
CRC Byte
5.5.5.2. PD Presence Detection Mode
“PP”
2 bytes
Presence Detection counter
4 bytes
CRC
1 byte
Where: “PP”: frame header
Presence Detection meter countingpeople detected as present = 0
CRC Byte
5.5.6. Parameters Command
5.5.6.1. Binary Frame
This command provides users with all parameter values in binary form and returns the
following frames:
“BP”
BPTD max range thresholds (millimeters)
Copyright © Terabee 2020
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
27/29