TeraRanger Evo 60m I2C ToF Distance Sensor User Manual
4.4.3
UART output format
Two output formats are available: 
Text 
output 
Data output in human readable form (5 to 7 bytes message): 
xxxxx\n 
- Distance reading in millimeters* (maximum 5 bytes per sensor):                 
xxxxx 
- New line character: \n (10 decimal / 0x0A hex) 
*please be aware that there is no zero-padding for leading zeros! 
- If the TeraRanger Evo is unable to measure a distance, it will output                         
-1\n as an error message 
- If the target is too close (below the minimum distance), the                     
TeraRanger Evo will output -Inf\n 
- If the target is too far away (above the maximum distance), the                       
TeraRanger Evo will output +Inf\n 
Binary 
output 
Data output (4 bytes message): 
TXXCRC8 
- Header (1 byte): T (84 decimal / 0x54 hex) 
- Distance reading in millimeters** (2 bytes): XX 
- Checksum (1 byte) of previous 3 bytes: CRC8 
**The TeraRanger Evo will output T01CRC (first distance byte set to zero                       
and the second to one) as an error message if the sensor is unable to                             
measure a distance: 
- If the target is too close (below the minimum distance), the                     
TeraRanger Evo will output T00CRC (both distance bytes set to                   
zero) 
- If the target is too far away (above the maximum distance), the                       
TeraRanger Evo will output TXXCRC with XX = FFFFhex (both                   
distance bytes set to 0xFF) 
Copyright © Terabee 2018 
Terabee, 90 Rue Henri Fabre, 01630, St Genis-Pouilly, France 
12/13 