Product Specifications
Copyright©Terabee2016
F
Fast
mode
This mode ensures fixed measurement repetition rates and reaction
times. This improvement comes at the expense of the reading accuracy
and maximum range which is limited to 4.5m in this mode. The delay
betweentworeadingsis1ms.
SensortypeB
O
Optimal
(Precise
mode for
Btype)
The TeraRanger One adapts its internal parameters to provide the best
available accuracy in sunlight conditions while providing high repetition
rates. The delay between two measurements is variable and depends on
the target distance and properties. This mode offers an optimized
performanceinoutdoorenvironments.
F
Fast
mode
This mode ensures fixed measurement repetition rates and reaction
times. This improvement comes at the expense of the reading accuracy
and maximum range which is limited to 4.5m in this mode. The delay
betweentworeadingsis1ms.
Youcanalsosettheoutputformatbysendingthecorrespondinguppercasecharacterto
theTeraRangerOneviatheserialport:
T
Text
output
Dataoutputinhumanreadableform(57bytesmessage):
xxxxx\r\n
Distance reading in millimeters* (maximum 5 bytes per sensor):
xxxxx
Carriagereturncharacter:\r(13decimal/0x0Dhex)
Newlinecharacter:\n(10decimal/0x0Ahex)
*please be aware that there is no zeropadding for leading zeros! If the
TeraRanger One is unable to measure a distance, it will output 1\r\n as an
error message. Valid measurements are decimal and between 200\r\n and
14000\r\n. Measurements at distances below 20cm or beyond 14m will
displaythe200\r\nor14000\r\nlimits.
90 Rue Henri Fabre Website:
01630 St. Genis‐Pouilly Technical support:
France (next to CERN) Commercial:
www.teraranger.com
support@teraranger.com
teraranger@terabee.com
12