Data Sheet
Copyright © Terabee 2017
Figure 2: TeraRanger Multiflex sensor dimensions in millimeters
The following aspects should be taken into consideration when mounting the TeraRanger
Multiflex:
● Do not remove the plastic covers as this will misalign the optics and degrade the
sensor’s performance.
● Sensors should not be connected or disconnected from the strip while the Multiflex is
powered.
● Do not mount the TeraRanger Multiflex Hub onto hot surfaces or near other sources of
heat. If possible, allow the board to properly radiate its heat or mount it in a ventilated
place.
● Take all usual precautions for sensitive electronics such as maintaining a suitable
distance from strong electric and magnetic fields, strong radio emitters, etc.
● Maintain clean mounting environment (dust entering behind the lens can severely
affect performance).
1.4 DetailsonSupplyVoltage
TeraRanger Multiflex Hub works with a supply voltage of 5V +-0.25V. Please make sure
that the supply voltage has low ripple and avoid strong inductive loads on the same supply
to keep it free of voltage spikes and drops.
Terabee Website:
90RueHenriFabre Technicalsupport:
01630Saint-Genis-Pouilly Commercial:
www.teraranger.com
support@teraranger.com
teraranger@terabee.com
5