Data Sheet

Copyright © Terabee 2017
Figure 2: TeraRanger Multiflex sensor dimensions in millimeters
The following aspects should be taken into consideration when mounting the TeraRanger
Multiflex:
Do not remove the plastic covers as this will misalign the optics and degrade the
sensor’s performance.
Sensors should not be connected or disconnected from the strip while the Multiflex is
powered.
Do not mount the TeraRanger Multiflex Hub onto hot surfaces or near other sources of
heat. If possible, allow the board to properly radiate its heat or mount it in a ventilated
place.
Take all usual precautions for sensitive electronics such as maintaining a suitable
distance from strong electric and magnetic fields, strong radio emitters, etc.
Maintain clean mounting environment (dust entering behind the lens can severely
affect performance).
1.4 DetailsonSupplyVoltage
TeraRanger Multiflex Hub works with a supply voltage of 5V +-0.25V. Please make sure
that the supply voltage has low ripple and avoid strong inductive loads on the same supply
to keep it free of voltage spikes and drops.