Data Sheet

Copyright © Terabee 2017
To send commands, the TeraRanger Multiflex uses a Python script. Please follow the
ReadMe file (available also under Support section on www.teraranger.com) from the
Python script to send the commands.
4 UART&USBProtocolDescription
4.1 BasicCommands(UART&USB)
Action type
Mode name / Action
Hex command
Modify PRINTOUT
MODE
TEXT
00 11 01 45
BINARY
00 11 02 4C
Configure the
number of sensors
to be used
To use all sensors (8 units)
00 52 FF 3E
To use only the first 4 sensors
00 52 03 0F E0
To use other amount of sensors
See Section 4.4
for configuration!
Answertothebasiccommands
Each time a command is sent, the user will receive an answer that will inform whether it is
an affirmative (acknowledge) or a negative (non-acknowledge) answer.
Action type
Type of answer
Hex command
Modify PRINTOUT
MODE
acknowledge
52 45 11 00 D4
non-acknowledge
52 45 11 FF 27
Configure the
number of sensors
to be used
acknowledge
52 45 52 00 B0
non-acknowledge
52 45 52 FF 43
Terabee Website:
90RueHenriFabre Technicalsupport:
01630Saint-Genis-Pouilly Commercial:
www.teraranger.com
support@teraranger.com
teraranger@terabee.com
18