Data Sheet

5 Communication
5.1UART protocol information
The UART communication for the TeraRanger Evo 64px uses a simple protocol via UART
depending on the backboard used with the sensor.
The communication parameters for UART are:
Baud Rate: 3000000
Data Bits: 8
Stop Bit(s): 1
Parity: None
HW Flow Control: None
5.2USB protocol information
The USB communication for the TeraRanger Evo 64px uses a simple protocol via USB
depending on the backboard used with the sensor.The communication parameters for the
USB VCP are:
Baud Rate: 115200
Data Bits: 8
Stop Bit(s): 1
Parity: None
HW Flow Control: None
5.3Commands
The user can send commands to configure the sensor to work in a specific mode. The frame
of the command is built concatenating 8 bit address of the TeraRanger Evo 64px, 4 bit
Command (CMD) code, 4 bit for data count (indicating how many bytes of data will follow), N
bytes of the data itself and a CRC-8 (8 bit) checksum of the entire frame in the last byte. The
layout is depicted in Figure 12.
Figure 12. Frame structure for Evo 64px commands
Copyright © Terabee 2018
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
13/22