User Manual
SUBMERSIBLE WATER PUMP
INSTRUCTIONS
EASY & CONVENIENT TO REPLACE WATER
PORTABLE ELETRIC FILTERING
1. MAIN PURPOSES OF THIS PRODUCT
2. NAME OF EACH PART
Make sure to use a discharge hose within 15mm thick.
Make sure to use a discharge hose within 10m long.
When supplying, you can raise the discharge hose up to
1.5m high maximum from the level of water in the supply
tank where you placed the pump.
When draining, you can raise the discharge hose up to 2m
high from the level of water where you placed the pump.
Make sure to place the discharge hose above the water
level in the water storage.
1
2
3
4
1
2
3
4
5
5
6
7
8
9
10
11
12
1 SWITCH
2 POWER CORD
3 POWER PLUG
4 POWER LAMP
5 PUMP CORD CONNECTOR
6 PUMP BODY
7 DISCHARGE PORT
8 PUMP CORD
9
PUMP PLUG
10
IMPELLER
11
IMPELLER CASING
12
FILTER
13
13
FRONT COVER
14
DISCHARGE HOSE
15
HOSE SPOUT
16
CLAMP FASTNER
3. HOW TO USE & PRECAUTIONS
If you slip the power supply adaptor into water, first make sure
to switch off and remove the end of the power supply and do
not reuse it.
HOW FLOW RATE WAS MEASURED: 3m HOSE USED.
THE DISTANCE FROM THE WATER SUPPLY SHOULD BE 2m.
6
Make sure to empty the remaining water in the hose,
otherwise the pump will not discharge water next time.
7
When cleaning up the pump, do not use thinner, benzene,
organic solvent, or glass cleaners.
8
When disposing of pump, make sure to have it completely
destroyed so that others won’t use it again.
When you hand it over to another person, be sure to give them
the instructions too.
Make sure to hold on the plug and pull it out from the outlet.
(Do not pull off the cable)
Rotate screws clockwise to fasten
hose clamps and fix discharge hose
with pump body. Hose-rings help you
to control the water discharge hose
in the right direction.
9
1
After use, empty the water in the discharge hose. (Completely
remove the water inside the hose)
2
Clean up the front cover and filter with water. (Turn the front
cover open to the left)
3
10
HOW TO MAINTAIN AFTER USE
HOW TO STABILIZE DISCHARGE HOSE
SPECIFICATIONS
APPLICATION
INPUT
OUTPUT
SIZE
PROTECTIVE
DEVICE
LENGTH OF
CORD
ITEM #
AVAILABLE
TEMP.
RANGE
FLOW
RATE
MAX AVAIL.
HEIGHT
LIFE SPAN
APPLICABLE
DISCHARGE
HOSE
2.6m FROM
THE GROUND
INNER DIAMETER
1.5mm
ABOUT 500 HOURS
(CONDITION: OPERATING
INTERVAL TIME 15MIN)
TRAQUA
SUBMERSIBLE ELECTRIC WATER PUMP
100V 50/60Hz 22VA
DC 12V 0.8A
Om FROM
THE GROUND:
12 LITERS/MIN
1m FROM
THE GROUND:
8 LITERS/MIN
1.5m FROM
THE GROUND:
7 LITERS/MIN
TEMPERATURE FUSE
0.9m FROM POWER SUPPLY ADAPTOR,
2.9m FROM PUMP BODY.
POWER SUPPLY ADAPTOR:
W67 X D56 X H100 (mm)
AMBIENT AIR TEMP::
5~35ºC
WATER TEMP.:
5~45ºC
PUMP BODY
58 (diameter) X 116mm
DISCHARGE HOSE
15 (diameter) X 29794mm
SAVE THESE INSTRUCTIONS.
READ ALL PRECAUTIONS AND INSTRUCTIONS.
WWW.TERAPUMP.NET
TERAPUMP@GMAIL.COM
1.877.251.2288
1941 E OCCIDENTAL ST
SANTA ANA CA 92705 USA
WITHIN 2m
WHEN DRAINING
DISCHARGE HOSE
MODEL. TRAQUA
WHEN SUPPLYING
WITHIN 1.5m
POWER CORD
PUMP CORD
1414
151
161
When supplying, be especially careful with and .
After submersing the pump, turn the switch on and use it, otherwise it
may cause malfunction. (If switch is on first, it may not pump water out)
3
5
REMOVING WATER from window wells, basements, boats,
inflatables, trays, washing machines, etc.
REPLACING WATER from ponds, aquarium, bathtubs, pools
and other water storage structures to keep water circulating.
FILTERING DIRTY WATER OR RAINWATER. Recycling filtered
water for multi-purposes.