Data Sheet
Specifications and data are subject to change without notice. Contact Tenergy for latest information.
©2018 Tenergy Corporation. All rights reserved.
Tenergy Corporation
436 Kato Terrace
Fremont, CA 94539
Tel: 510.687.0388 Fax: 510.687.0328
www.Tenergy.com email: sales@tenergy.com
9 PCM performance
10 Label(SIZE:62*74.5mm)
Item
Content
Criterion
Over charge Protection
Over charge detection voltage
4.30±0.035V
Detection delay time
120±80mS
Over charge release voltage
4.100±0.050V
Over discharge protection
Over discharge detection voltage
2.500±0.1V
Detection delay time
50±30mS
Over discharge release voltage
2.90±0.100V
Over current protection
Over current detection current
12±3A
Release condition
Disconnect the load
Detection delay time
10±4mS
Maximum continuous discharge current
≤5.5A
Short protection
Detection condition
Exterior short circuit
Release condition
Charging activation
Interior resistance
Main loop electrify resistance
RSS≤35mΩ
Current consumption
Current consume in normal operation
≤40μA
Usb port charge current
0.75A±30mA
PCB Dimension(L*W*H)mm
17.6*0.8MM