Indoor Fireplace User Manual

15
Temco DV5200 Series
78674
8. To finish connections, place a small bead of silicone
to the outside of the fireplace inlet flange. Then, slide
the extension collar over the inlet flange and secure
with the three (3) screws provided.
NOTE: We recommend driving in two (2) sheet metal
screws at 180° adjacent to the gear clamp at each joint.
Flex Vent Through the Roof
(Vertical) Applications
All models are approved for:
1. Vertical venting up to 35’ (10.7 m) with 7” x 4” flex.
2. Multiple bends allowed. See section on General
Venting.
3. With each vertical installation, a VSK7MH-2 kit may
be used.
T190
ceiling install
12/5/03 djt
Room Above
Ceiling Level
Ceiling Joist
Firestop
T190
Fig. 23 Firestop at ceiling level.
T190
ceiling install
12/5/03 djt
Firestop
Attic Above Ceiling
(Uninsulated)
Attic Above Ceiling
(Insulated)
Attic Insulation
Shield
T190
Fig. 24 Attic insulation shield.
6' (1.8m)
Maximum
35' (10.7m)
Maximum
T191
thru the roof
installation
12/5/03 djt
Roof
Attic Insulation
Shield
7” (178 mm) Dia.
Joists
T191
Fig. 25 Typical through-the-roof installation.
The VSK7MH-2 Kit contains:
Vertical Termination Cap and Storm Collar
4”/7” dia. x 24” Rigid Pipe (unitized)
7” dia. Roof Support Components
10’ Length of 4” x 7” Aluminum Flex Vent w/Clamps
Adjustable Firestop Thimble Assembly
0/12-5/12 Flashing with Storm Collar
Tube High Temp Sealant
7” dia. Inlet Ext. Collar
Firestop
Hardware Pack
Instruction
VSK7MH-2 Vertical Flex
Vent Kit Installation
1. Locate the fireplace.
2. Mark ceiling above unit where flex will come through.
*-REFER TO VERTICAL TERMINATION LOCATION
CHART
3. Ceiling opening should be a minimum of 9
¹⁄₂” x 9¹⁄₂
(241 x 241 mm) and framed to that size.
4. Mark opening in roof and cut a hole minimum 9¹⁄₂” x
9¹⁄₂” (241 x 241 mm) and frame to that size.
5. Place fireplace in proper location and secure to the
floor.
6. Install the firestop thimble assembly at the ceiling
level.