INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier.
TDVN Series Direct Vent Gas Fireplace Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions General Information, Warnings, Cautions..............................
TDVN Series Direct Vent Gas Fireplace Installation & Operating Instructions This gas fireplace should be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54. FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING: 1 .
TDVN Series Direct Vent Gas Fireplace Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.
TDVN Series Direct Vent Gas Fireplace Fireplace Dimensions Rough Opening Depth R E H O F R Q N- Rough Opening Width Rough Opening Height P G B M D C Gas Line Access L I Electrical Access Low Voltage Electrical Access A 1" (25mm) I Gas Line Access Fig. 1 Fireplace specifications and framing dimensions. Ref.
TDVN Series Direct Vent Gas Fireplace V Locating Your Fireplace W X Y Y A E X C Y Z B A D X B C D E B Fireplace Top Louvre Assembly F LU584-T Fig. 2 Locate gas fireplace. LU584-T unit -Locating **Island 12/18/02 djt A - Flat on wall B - Cross corner C D - Room divider E - Flat on wall corner F - Chase installation Y - Refer to “Clearance to Combustibles” Section Note (Fig.
TDVN Series Direct Vent Gas Fireplace Hearth Final Finishing A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.
TDVN Series Direct Vent Gas Fireplace Gas Line Installation When purging gas line, the front window frame assembly must be removed. 1. The gas pipeline can be brought in through the rear of the fireplace as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection.
TDVN Series Direct Vent Gas Fireplace It is strongly suggested that the wiring of the EB-1 Electrical Junction Box be carried out by a licensed electrician. Remote ON/OFF Switch or Thermostat or Remote Control TP TH TP Ensure that the power to the supply line has been disconnected before commencing this procedure. Gas Control Valve The EB-1 Electrical junction box has been fitted standard on this model to allow for the easy connection of an optional fan kit.
TDVN Series Direct Vent Gas Fireplace General Venting Your fireplace is approved to be vented either through the side wall, or vertical through the roof. • • • • 10 Only CFM Corporation venting components specifically approved and labelled for this fireplace may be used. Venting terminals shall not be recessed into a wall or siding. Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope.
TDVN Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A N N D V L E C B V F B ����� ������ Ope B V Operable rable V B B B J X X AIR SUPPLY INLET M I A CFM145a V VENT TERMINATION V V Fixed Closed C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (610mm) from the center line of the terminal E = Clearance to unventila
TDVN Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner G= Combustible 6" (152 mm) G F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. M M No.
TDVN Series Direct Vent Gas Fireplace Twist Lock Pipes 30 29 28 27 26 25 24 23 To join the twist lock pipes together, simply align the beads of the male end with the grooves of the female end, then while bringing the ends together, twist the pipe until the flange on the female end contacts the external flange on the male end. It is recommended that you secure the joints with three (3) sheet metal screws, however this is not mandatory with twist lock pipe.
TDVN Series Direct Vent Gas Fireplace 20' (6m) 7.5' (2.3m) A Pipe Straps Every 3’ (914mm) 7.5' (2.3m) Pipe Straps Every 3’ (914mm) B 1 x 90° elbow in horizontal plane = 3’ (914mm) Firestop/Zero Clearance Sleeve A + B = 17' (5.2m) Max. FP1012 Fig. 13 Support straps for horizontal runs. FP1238 Horizontal plane means no vertical rise exists on this FP1012 portion of the vent assembly. Fig. 15 Maximum vent run with elbows.
TDVN Series Direct Vent Gas Fireplace Vent Opening for Combustible Wall 9³⁄₈” (240mm) Framing Detail 9³⁄₈” (240mm) X Fireplace Hearth Opening for Noncombustible Wall FP1240 7¹⁄₂” (190mm) Fig. 19 Vertical height requirement. VO584-100 Fig. 17 Locate vent opening on wall. Noncombustible Walls: (Fig. 17) Hole opening must be 7¹⁄₂” (190 mm) in diameter. STEP 2 Measure wall thickness and cut zero clearance sleeve parts to proper length (MAXIMUM 12”/305 mm).
TDVN Series Direct Vent Gas Fireplace Support horizontal pipes every 3’ (914 mm) with metal pipe straps. Make sure the horizontal vent pipe is installed on a level horizontal plane. Vertical Sidewall Installation Flex Vent Pipe NOTE: The 40” (1016 mm) flex vent is used for 90° off the top of the unit then out the back wall. Follow Step 1 and 2 on Page 14. Step 3 FP1242 Fig. 21 Through the wall.
TDVN Series Direct Vent Gas Fireplace Step 4 Install the 4” (102 mm) flex vent pipe to the termination cap collar as described on Page 11. Step 5 Slide the 7” (178 mm) flex vent pipe over the 4” flex vent pipe and secure the 7” collar as described on Page 11. Step 6 Bend the flex pipe horizontal so the bottom of the horizontal pipe measure 6¹⁄₂” (165 mm) from the top of the unit immediately after the 90° formation. (Fig. 25) Be sure to follow the 1/2” (13 mm) rise in a 12” (305 mm) horizontal run rule. 3. 4.
TDVN Series Direct Vent Gas Fireplace Vertical Through-the-Roof Applications This Gas Fireplace has been approved for: • Vertical installations up to 40’ (12 m) in height. Up Max. 8' (2.4m) to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig. 28) 4 1 + 2 + 3 + 4 = 270° Max. Height 40' (12m) Max. 10' (3m) 3 Min. Height 7¹⁄₂' (2.3m) 2 1 Pipe Straps Every 3’ (914mm) FP1245 FP1244 Fig. 28 Support straps for horizontal runs.
TDVN Series Direct Vent Gas Fireplace Vertical Restrictor Plate (33TDVN only) Attic Insulation Shield When installing the 33TDVN with a Vertical Throughthe-Roof configured flue system the restrictor plate, (#10002495) supplied with the appliance MUST BE FITTED TO THE APPLIANCE at installation. Joist Install restrictor plate to firebox top using two (2) screws. Ceiling Installation 11" (279mm) 11" (279mm) Upper Floor Joist Firestop Spacer The legs of the restrictor plate must go up.
TDVN Series Direct Vent Gas Fireplace If there is a room above ceiling level, firestop spacer must be installed on both the bottom and the top side of the ceiling joists. If an attic is above ceiling level a 7DVAIS (Attic Insulation Shield) must be installed. Min. 2’ (610 mm) The enlarged ends of the vent section always face downward. (Fig. 35) CFM190 Fig. 36 Minimum termination to roof clearance. CFM190 TTR Ternim.
TDVN Series Direct Vent Gas Fireplace Twist Lock Venting Components 7TDVSK - Through the wall Rear Vent Termination Starter Kit Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) Model 7FDVSK - Sidewall Venting (Flex Vent Pipe) 584A venting components rear vent term 4/6/99 djt Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit for Below Grade Installation Model 7TDVSKS -Snorkel Kit
TDVN Series Direct Vent Gas Fireplace Operating Instructions Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will • • • void all product warranties. Care must be taken to avoid breakage of the glass. Do not operate appliance with glass front removed, cracked or broken.
TDVN Series Direct Vent Gas Fireplace Installation of Logs, Lava Rock & Ember Material Unpack the logs from packaging and remove each log from its wrapping materials. The logs are fragile and should be handled with care. Keep the packaging material out of the reach of children and dispose of the material in a safe manner. The embers supplied with your fireplace are made from a high grade rock wool and should be handled carefully. Wash your hands immediately after touching to avoid irritation.
TDVN Series Direct Vent Gas Fireplace Flame & Temperature Adjustment For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustments knob located near the center of the gas control valve. (Fig. 42) HI Turn counterclockwise to increase flame height LO Turn clockwise to decrease flame height Fig. 42 Flame adjustment knob for SIT valve. FP1229 Fig. 43 Correct pilot flame appearance.
TDVN Series Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas.
TDVN Series Direct Vent Gas Fireplace Troubleshooting SIT Millivolt Valve NOTE: Before troubleshooting the gas control system, be sure external shut off is in the “ON” position. WARNING: Before doing any gas control service work, remove glass front! Table 1 Valve Type NOVA MV Plus Main Operator Minimum Voltage 145mV Coil Resistance 2.25Ω ± 0.5Ω Safety Magnet Hold-in Current Less than 285mA Drop-out Current Greater than 125mA Coil Resistance 0.108Ω ± 0.003Ω System Checks Problem Pilot will not light.
TDVN Series Direct Vent Gas Fireplace System Checks (continued) Problem Possible Cause Defective thermo-generator. (Millivolt system) Defective safety magnet. (mv Plus systems) Defective Safety Magnet (Millivolt system) Pilot orifice blocked. Pilot drops out. Wrong pilot orifice. No gas to main burner Low gas pressure to appliance. Pilot not lit. Control knob not in ON Thermostat/wall switch will not cycle main burner. 20007636 Thermostat not in ON position.
TDVN Series Direct Vent Gas Fireplace System Checks (continued) Problem Possible Cause Solution Thermo-generator output voltage not within design parameters. After the pilot has been lit for approximately three minutes, and only the thermo-generator wire connected to the main operator head, measure the voltage across TPTH and TP. This open circuit voltage should be between 500mv and 750mv. Tune the pilot adjustment screw until the mv reading falls within these parameters.
TDVN Series Direct Vent Gas Fireplace Fuel Conversion Instructions WARNING: This HI/LO conversion kit must ONLY be applied as part of a conversion kit supplied by the appliance manufacturer for the specific appliance and type of gas being converted. The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CSA B149.
TDVN Series Direct Vent Gas Fireplace Conversion Parts Included with Kit Main Burner Orifice - LP Label, Conversion Pilot, Orifice - LP Conversion Pressure Regulator Assembly - LP Label, SIT Valve Kit Number 36DVCKP 20007908 10002876 76263 74655 -- 33DVCKP 76776 10002876 76263 74655 -- Replace Pilot Orifice LPG 39DVCKP 20007907 10002876 76263 74655 -- NG 1. The pilot hood is held in place by spring pressure. Remove the hood by pulling it directly up from the pilot bracket. (Fig. 47) 2.
TDVN Series Direct Vent Gas Fireplace Pressure ranges are: A Gas Supply Pressure (inches w.c.) Minimum Normal Maximum LP (Propane) 10.8 11.0 14.0 Manifold Pressure (inches w.c.) Nornal (HI) Normal (Low) LP (Propane) 10.0” 6.3” B Manifold pressure can be measured by using a 5/16” I.D. hose in the right hand side of the valve and connecting a manometer. Two test gauge ports are accessible for test gauge connection: C 1. Tap on left side of the valve will give inlet supply pressure. 2.
TDVN Series Direct Vent Gas Fireplace Unit Adjustment Once installed, the unit should be operated at least three (3) times to ensure that all is in working order. NOTE: Manufacturing oils will smoke during initial firing of appliance. Open windows for ventilation.
TDVN Series Direct Vent Gas Fireplace Maintenance Motor and Blower for Fan Kit (optional) This motor has been factory oiled and under normal operating conditions should not require oiling. WARNING: Ensure the power is turned off to the fireplace before servicing. Cleaning This unit should be cleaned and serviced by a Qualified Gas Technician at least annually. More frequent cleaning may be necessary if pet hair accumulates, dust and lint are present, or if the unit is located in a high traffic area.
TDVN Series Direct Vent Gas Fireplace Model 33TDVN 33TDVP 36TDVN 36TDVP 39TDVN 39TDVP Model 33TDVN 33TDVP 36TDVN 36TDVP 39TDVN 39TDVP Normal and High Direct Vent Units - Inputs - Orifice Size - Altitude BTU/Hr BTU/Hr Manifold Pressure Orifice 0 - 2000ft. Altitude in USA Min. Input Max. Input @ Max. Orifice 0-4500ft Altitude in Canada 12,500 18,000 3.5”w.c. .079” 12,500 18,000 10.0” w.c. #56 DMS 13,000 20,000 3.5” w.c. #45 DMS 14,500 20,000 10.0” w.c. #55 DMS 15,000 22,000 3.5” w.c. #43 DMS 16,500 22,000 10.
TDVN Series Direct Vent Gas Fireplace 33TDVN Logs 1 4 36/39TDVN Logs 1 1a 1b 1c 1b 1d 1c 11 1d 1a 3 2 12 14 16 13 7 21 18 19 26 27 28 33 31 30 35 29 7636 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. TDVN Series Gas Fireplace Heater Units: GF1AT1, GF1AT2, GF1AT3 Ref. 1. 1a. 1b. 1c. 1d. 2. 3. 4. 5. 6.
TDVN Series Direct Vent Gas Fireplace TDVN Series Gas Fireplace Heater (continued) Ref. 7. 8a. 8b. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 29. 30. 31. 32. 33. 34. 35. 36. 36 Description Pilot Assembly, SIT Top Convertible - Nat. Pilot Orifice - LP (not shown) Pilot Orifice - Nat. (not shown) Rep. Reg. Assembly - LP, HI/LO 82979 (not shown) Rep. Reg. Assembly - Nat.
TDVN Series Direct Vent Gas Fireplace Optional Accessories Fan Kits Thermal Sensor Fan FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit. Specifications 115 Volt / 60Hz / 56 Watts Maintenance The fan itself does not require regular maintenance, however periodic cleaning of the fan and the surrounding area is required.
TDVN Series Direct Vent Gas Fireplace Wiring Instructions The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code. For USA installations follow the local codes and the national electrical code ANSI/NFPA No. 70. Should this fan require servicing or repair the power supply must be disconnected. For rewiring of any replacement parts refer to Figure 53.
TDVN Series Direct Vent Gas Fireplace Top Louvre Bay Window Frame Ceramic Refractory Ceramic Refractory Bottom Louvre Assemblies Bottom Brass Trim CFM178 Screws FP1234 Fig. 58 Bay window screen assembly. Fig. 57 Bay window installation. Bay Window Screen FP1234 Bay Window Screen Kits are available for the 33TDVN, 36TDVN & 39TDVN model Bay appliances. window 11/02 window frame Do not remove existing assembly! Remove all plastic from brass trims.
TDVN Series Direct Vent Gas Fireplace Limited Warranty TEMCO Fireplace Products Direct Vent Gas Fireplaces This warranty is limited to CFM Fireplace Products Direct Vent Gas Fireplaces (henceforth, Product) manufactured by CFM Corporation (henceforth, CFM). approval for warranty repair or replacement and to affect a warranty claim. The Checklist is found on Pages 40 and 41 of this manual.
TDVN Series Direct Vent Gas Fireplace TEMCO FIREPLACE PRODUCTS DIRECT VENT FIREPLACES INSTALLATION AND STARTUP CHECKLIST Customer Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement. ❑ Read and understand installation instructions before attempting installation.
TDVN Series Direct Vent Gas Fireplace TEMCO FIREPLACE PRODUCTS DIRECT VENT FIREPLACES INSTALLATION AND STARTUP CHECKLIST Installer’s Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement. ❑ Read and understand installation instructions before installing.
TDVN Series Direct Vent Gas Fireplace Customer Copy Model # ______________________________________ Serial # ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO Fireplace Products installation instructions. I have completed the proper installation and startup checklist.
Efficiency Ratings Model 33TDVN 33TDVP 36TDVN 36TDVP 39TDVN 39TDVP EnerGuide Ratings Fireplace Efficiency (%) 54.2 54.2 54.89 54.89 61.8 61.8 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.