Indoor Fireplace User Manual

34
TDVN Series Direct Vent Gas Fireplace
20007636
T203
Air shutter
12/12/03 djt
T203
Opening
“A”
Fig. 51 Air shutter opening.
Normal and High
Direct Vent Units - Inputs - Orifice Size - Altitude
BTU/Hr BTU/Hr Manifold Pressure Orifice 0 - 2000ft. Altitude in USA
Model Min. Input Max. Input @ Max. Orifice 0-4500ft Altitude in Canada
33TDVN 12,500 18,000 3.5”w.c. .079”
33TDVP 12,500 18,000 10.0” w.c. #56 DMS
36TDVN 13,000 20,000 3.5” w.c. #45 DMS
36TDVP 14,500 20,000 10.0” w.c. #55 DMS
39TDVN 15,000 22,000 3.5” w.c. #43 DMS
39TDVP 16,500 22,000 10.0” w.c. #54 DMS
Conversion Kits
Change Natural Change Propane
Model to Propane to Natural
33TDVN 33DVCKP --
33TDVP --
36TDVN 36DVCKP --
36TDVP --
39TDVN 39DVCKP --
39TDVP --
IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.
Air Shutter Settings
Opening
Model “A”
33TDVN 1/32” (1.0 mm)
33TDVP 3/8” (9.5mm)
36TDVN 1/32” (1.0 mm)
36TDVP 3/8” (9.5mm)
39TDVN 1/32” (1.0 mm)
39TDVP 3/8” (9.5mm)
NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.