User's Manual

56034903 © 2008 Telular Corporation
25
A4.0 UL Installation Requirements Summary
Household
Burglary
Household
Fire
Household
Burg/Fire
Combination
Central
Station
Burg
Police
Connect
Burg
Bank,
Safe and
Vault
TG-7
TG-7
TG-7
TG-7A
TG-7A
TG-7A
Telguard Model Required.
O
O
O
Y
Y
Y*
UL Listed Bell and Bell
Housing **
O
O
O
O
O
Y
AC transformer lines in
rigid conduit.
Y
Y
Y
Y
Y
Y
AC transformer plugged into
un-switched outlet.
O
O
O
O
O
Y
AC transformer plugged into
dedicated branch circuit.
O
O
O
O
O
Y
AC transformer enclosed in
Listed pull box (example:
Hoffman A-SG8x8x6).
-
-
-
N
N
N
PBX connection to RJ31X
jack.
O
O
O
Y
Y
Y
Enclosure Tamper Switch
connected to 24-hour circuit.
O
O
O
Y
Y
Y
Antenna cable in flexible
conduit concealed or covered
by motion detector.
O
O
O
Y
Y
Y
Attack resistant enclosure
(APC-32S).
24 hrs.
Use
7Ah.
24 hrs.
Use
7Ah.
24 hrs.
Use
7Ah.
24 hrs.
Use
7Ah.
24 hrs.
Use
7Ah.
72 hrs.
Use
14Ah.
12V Battery backup
requirement.
O=Optional (Not Required) Y=Yes (Required) N=No (Not Allowed)