User's Manual

56034903 © 2008 Telular Corporation
10
NOTE: SPECIAL LED INDICATIONS DURING ACTIVATION
IF THE TELGUARD FAILS THE REGISTRATION PROCESS IT WILL BE DISPLAYED ON THE LEDS.
1. IF LED #1 AND LED #4 ARE FLASHING, THE TELGUARD SERIAL NUMBER IS NOT IN THE DATABASE AT THE
TELULAR COMMUNICATION CENTER, CALL TECHNICAL SUPPORT TO VERIFY PROPER LINE RANGE.
2. IF ALL OF THE LEDS ARE FLASHING, THE REGISTRATION MESSAGE WAS NOT RECEIVED AT THE
TELULAR COMMUNICATION CENTER. RETRY TRANSMITTING REGISTRATION MESSAGE. IF TELGUARD
FAILS A SECOND TIME TO REGISTER, CHECK SIGNAL STRENGTH. IF SIGNAL STRENGTH IS OK, THEN
CALL TECHNICAL SUPPORT.
ON EITHER INDICATION OF FAILED REGISTRATION, THE UNIT MUST BE RESET
BY “SHORTING” J10 (RSSI
JUMPER) , THE REGISTRATION MESSAGE MUST BE RESENT
OR THE TELGUARD WILL TRANSMIT ALL
SIGNALS THROUGH THE TELCO CONNECTION.
SYSTEM STATUS LEDS REGISTRATION INDICATIONS
ALL LEDS FLASHING FAILED REGISTRATION – SIGNAL TOO WEAK
LED #1 & LED #4 FLASHING REGISTRATION ERROR – CALL TECHNICAL SUPPORT
LED #1 ON REGISTRATION SUCCESSFUL
LED #2 SOLID NOT REGISTERED NEED TO CONNECT PANEL AND TRIP ZONE
SYSTEM TROUBLE CONDITION, STC (LED #2)
STATUS LED #2 INDICATION
1 FLASH AC LOW/MISSING
2 FLASH LBC LOW BATTERY and/or BATTERY CHARGER FAIL
3 FLASH LFC LINE FAULT
4 FLASH NSC NO SERVICE
5 FLASH RFC RADIO FAILURE
6 FLASH DTF DIAL TONE FAIL
5.3.1 Setup & Programming the Operating Parameters in the Telguard
When the Telguard is received from the factory and is powered up for the first time, it is immediately ready for
registration, provided the default settings are what you want. The STC LED #2 will flash to indicate any failure
conditions. The Mode LED #3 will be on and the STC 1 and STC 2 relays will be tripped. If changes are
required to the default settings, the Telguard can be programmed using a line-mans butt-set connected to T &
R Test Points or a POTS phone connected to J7 (black connector where the C/C is normally connected).
5.3.1.1 Command Key Sequences for Pots Programming
Key Sequence Description
# * Enters the programming Mode
*
Exits programming and stores changes
TO PROGRAM THE TELGUARD
A. Put the line-mans butt-set in talk mode or pick up the POTS phone,
B. Connect power to the Telguard, when ready for programming you will hear 2 beeps
C. Press #, *, this will put the Telguard into a Master Access programming mode, 2 beep.
D. Enter changes required
The syntax for programming a specific memory location is as follows:
MEMORY LOCATION (3-digits), will respond with 2 beeps, then VALUE, will respond with 2
beeps.
E. Press *, you will hear 2 beeps then hang up. This saves the change and exits the
programming mode.