User's Manual
56019201
Pag
e
© 2000 Telular Corporation
34
A3.3 N
OTES TO
I
NSTALLATION
/W
IRING
R
EQUIREMENTS ON
A
PPENDICES
A3.1
AND
A3.2
(Must use Telguard Model T300C001 for Commercial Burglary applications. Telguard Model
T200C001 is acceptable for Residential Burglary applications.)
A.
All cables between the host burglary alarm control communicator (C/C) and Telguard model T300C001
must be enclosed in rigid conduit. Antenna cable may be enclosed in flexible conduit concealed within
building structure or in field of vision of motion detector (if commercial burglary, UL1610, see Note
D
).
•
Host burglary alarm C/C and Telguard must be within 3 feet of each other.
B
.
Tamper switch on door of Telguard must be connected to instant 24 hour initiating circuit of host
burglary alarm C/C.
C.
Must use Listed burglary alarm central station control with integral or Listed remote DACT installed
according to manufacturer's instructions. (For central station use only).
D.
The Telguard antenna must be installed indoors in an area concealed from field of vision and in an area
where access is protected by Listed motion detector. The motion detector must be connected to an
instant-armed initiating circuit of host burglary alarm C/C
∗
. Example: If the antenna is placed above a
drop ceiling, the motion detector must protect the room below the antenna. (Not required for residential
use).
E.
Transformer must be connected to unswitched AC outlet.
F.
Incoming Telco is connected to J1. Direct Telco line connection required. No PBX.
•
Ring-back opening and closing is done over the DACT and the 24-hour check-in is done over both
lines.
G.
In “TELCO PRIMARY/RADIO SECONDARY” or “RADIO ONLY” configurations, use a Listed bell
and bell housing (for example, Ademco AB-12, etc.) installed according to manufacturers instructions in
order to maintain Grade A. Grade B available without bell and bell housing.
H.
Tamper resistant housing supplied with model T300C001 is required for commercial burglary UL1635,
but not required for residential burglary, residential fire, or commercial fire UL864. Use model
T200C001 with standard metal enclosure for residential burglary, residential fire, or commercial fire
UL864.
J.
Additional requirements for UL Bank Safe and Vault Service:
•
Two 7Ah batteries and harnesses must be used to meet the minimum UL required 72-hour standby
time in case of power failure.
•
The unit must be mounted inside of the bank safe or vault. If mounted outside the safe, the enclosure
shall be lined or used in conjunction with a Listed compatible shock sensor.
•
The unit must be connected to a Control Unit that is UL Listed for Bank Safe and Vault Service.
∗
- Motion detector required for commercial burglary UL1610, but not for residential burglary, residential
fire, or commercial fire UL864.