User's Manual

56020801
Pag
e
© 2000 Telular Corporation
12
5.2.4 Default Programming
The Telguard default setup is pre-programmed at the factory. Default setup values are listed in
Section 5.2.5 (
Telguard Programming Data Sheet)
and highlighted in "
bold
" type. Setup
parameters are stored in non-volatile memory and retain their settings when power is removed from
the unit. Review the default settings and record on the data sheet all changes that you make.
Typically, the only critical programming entries are:
Memory Location Field
32
*
Cellular System A or B
33
**
Enter the 1-digit C/C Reporting Format
* Note:
The Cellular carrier is factory defaulted to the "B" carrier. If the cellular carrier in your
area providing Microburst™ service is an "A" carrier, then memory location 32 must be
reprogrammed to 1. (Refer to the following Telguard Programming Data Sheet, location 32).
**Note:
The C/C Reporting Format is already factory defaulted to Ademco Contact ID. Refer to
Telguard Programming Data Sheet, location 33.
5.2.5 Complete the Telguard Programming Data Sheet
Fill out the following
Telguard Programming Data Sheet
. The completed data sheet enables you
to properly install and test the Telguard as well as provide a valuable aid to future troubleshooting
if it becomes necessary. Detach and retain this data sheet in your customer account file for future
reference.
Customer Name: Dealer No: Telguard Serial No:
Installation Location:
Date Installed: Installed By:
MEM
LOC.
FIELD DEFAULT
VALUE
NEW PROGRAM
VALUE
SETTING
32
Cellular System A or B
2
1=System A
2=System B
33
C/C Reporting Format
8
1=4 x 2 Pulse 40 PPS 2300 Ack (Double Round) Non-Extended
2=4 x 2 Pulse 20 PPS 2300 Ack (Double Round) Non-Extended
3=4 x 2 Pulse 20 PPS 1400 Ack (Double Round) Non-Extended
4=3 x 1 Pulse 40 PPS 2300 Ack (Double Round) Non-Extended
5=3 x 1 Pulse 20 PPS 2300 Ack (Double Round) Non-Extended
6=3 x 1 Pulse 10 PPS 1400 Ack (Double Round) Non-Extended
7=Radionics Modem IIE or 3A
2
8=Contact ID (Ademco) 1400/2300 Ack
51
STC Trip Output Reporting
31
Enter the
SUM TOTAL
of the events that you wish to trip the STC relay
by
ADDING
the corresponding values:
(ex: 01+02+08+16=27) Note that a LFC will not trip the STC relay.
Program 31 (27+04) for all supervised features to trip the STC relay.
00 = STC Trip Input Not Used
01 = AC Failure 04 = LFC
16 = RFC
02 = Low Battery 08 = NSC
52
STC Trip Delay for LFC and NSC
2
1=30 Seconds
2=60 Seconds
61
CFC Number of Attempts
2 0=Disabled
2=4 Attempts
1=2 Attempts 3=8 Attempts
62
CFC Between Events
1 1=30 Seconds
2=60 Seconds
67
Standby Battery Size
(standard lead-acid battery)
44=7 Amp Hour
5=14 Amp Hour
99
Factory Default Values
12345
Returns EEPROM to original factory settings.