5.2.2 Connect Backup Battery and AC Power Transformer
To apply power on models T200C001 or T300C001 attach battery leads to terminals
3 (-)
and
4 (+)
noting polarity and program Telguard memory location 67 (see section 5.2.5) for proper battery
capacity.
Connect the Telguard AC power transformer to terminals
6
and
7
marked "
AC 16.5V 20VA
" using
stranded copper insulated wire following wire gauge and length recommendations below:
Recommended Wire Size Length Not to Exceed
18 ga 20 ft
16 ga 40 ft
14 ga 60 ft
5.2.3 Decide on a STC Trip Output Strategy
The Telguard provides the host C/C with one supervisory trip output for reporting a Telguard
system trouble code to the central station. The supervisory trip output (terminals 1 & 2, N.O.) is
programmable via a touch-tone telephone or buttset to suit various installation requirements. The
programming options for this supervisory trip output can be any combination of the following
(except Always off):
a.
Always Off:
Disables all relay supervisory functions with relay in N.C. condition.
b.
ACFC:
Trips 6-hours after loss of AC power. Restores 60 seconds after AC power is restored.
c.
LBC:
Trips within 60 seconds on low battery condition. Restores when battery voltage
12.1
vdc.
d.
LFC:
Trips 30/60-sec. on Telco line fault condition. Restores 30/60 seconds after Telco line
restores.
e.
NSC:
Trips 30/60-sec. on no service condition due to loss of RF signal strength. Restores
30/60 seconds after RF signal strength is available.
f.
RFC:
Trips on radio failure to communicate with the Telular Communication Center due to
either of the following:
1.
Failing to receive a Link Request acknowledgement from the Communication Center
after 3 Link Request transmissions. A Link Request transmission is generated each
time the C/C goes off-hook to dial when the Telguard is in radio mode. The Link
Request acknowledgment from the Communication Center allows the Telguard to
begin accepting and transmitting alarm data from the C/C.
2.
Failing to receive a Link Termination acknowledgement from the Communication
Center after 2 complete transmission retries. A Link Termination acknowledgement
is generated by the Communication Center only when all messages in an alarm
transmission have been received successfully.
Refer to Appendix A3.3.1 for UL supervisory requirements for Listed burglary configurations and
Appendix A3.5.1 for Listed fire configurations.