1. Be sure your unit has cellular service activated. (See Section 3.0)
2. Be sure you have all the proper parts before you go to the job site. The following items are shipped with
each Telguard unit:
"
Basic Telguard unit (Model T200C001 in standard metal enclosure, or Model T300C001 in attack
enclosure with tamper switch).
"
16.5 VAC, 20 VA UL Listed plug-in transformer (Revere, P/N: RT-1620SL).
Note: The 20 VA transformer is required for proper operation since the Telguard is
capable of transmitting at 3 watts of output power. Do not use the C/C power
transformer to provide AC power to the Telguard.
"
Antenna: Magnetic-mount 3dB-gain antenna with 12ft. cable for T200C001 or 5dB-gain antenna for
T300C001.
"
3-foot modular plug-to-plug cord for connecting Telguard to RJ31X jack.
"
Telguard Installation and Operating Instructions Manual, P/N: 56020801
"
Account Activation and Programming form documenting the unit's electronic serial number, cellular
telephone number, etc.
NOTE: Backup batteries are not supplied with any models. You must source backup batteries
separately. The T200C001 and T300C001 have flying leads with terminals for convenient plug-in
connections to the larger capacity batteries.
All Telguard Models Approx. Standby
Time
12V. Battery
Capacity
Manufacturer/model
24-Hours 7.0 Ah Technacell EP 1270T200C001/T300C001
72-Hours 14.0 Ah (2 ea. 7.0
Ah)
Technacell EP 1270
3. You must also have certain installation test tools.
•
A standard telephone or lineman's buttset is required at the job site for use in programming the unit.
•
Optimal signal strength is determined by placing the unit where the most LEDs (up to four) are
lighted when using Telguard's on-board Signal Strength Indicator feature so that the unit can be
easily placed during installation where signal strength is greatest.
NOTE: Your unit may be subject to airtime charges for unintended use. Telular offers several cellular
service rate plans. Check the Activation and Programming form that was shipped with your unit
or call us to determine what rate plan each unit is operating under.
4.0 INSTALLATION SUMMARY
There are five steps in installing Telguard properly.
IF YOU DO NOT PROCEED IN THE ORDER AND
MANNER PRESCRIBED, YOU MAY NOT COMPLETE THE INSTALLATION IN THE TIME
ALLOCATED.
These five steps are summarized below and then explained in detail in the remainder of this manual.
4.1 T
RANSMIT
C/C A
LARMS OVER THE
T
ELCO
C
ONNECTION
First, make sure you can transmit alarm signals from the C/C host to the central monitoring station
over the
telco line without any connection to Telguard.
4.2 P
ROGRAM
T
ELGUARD AND
C
ONFIRM
C
OMMUNICATIONS
I
NTEGRITY
Next, you will be confirming that Telguard's programming parameters are correctly entered into the unit and cellular
service is activated.
This is the most important step in the installation, since the programming parameters
contain all the necessary information for successful communications.
Also, you will confirm that Telguard has
adequate cellular signal strength.
4.3 T
RANSMIT
C/C A
LARMS OVER THE
C
ELLULAR
R
ADIO
N
ETWORK
Next, you will be connecting the C/C's digital dialer output to Telguard and verifying that alarm signals can
be reliably sent through Telguard over cellular to the central station digital receiver. The incoming Telco
line is not connected to Telguard during this step.