User's Manual
56019201
Pag
e
© 2000 Telular Corporation
20
Exhibit 1. Telco Signal Path through Telguard
RJ31X
HOST C/C
PREMISE PHONES
INCOMING TELCO
SIGPATH0.VSD
23
4
5
6
7
T
GREEN
R
RE D
R1
BROWN
T1
GREY
8
T1 T R R1
J1
T1 T R R1
J2
Telco Voltage
Measurement
House Phone
Current
Measurement
Dialer Current
Measurement
1
Internal Circuitry
Telco Dialer
T1 T R R1
TELGUARD
5.4.2 Connect RJ31X to Telguard Jack 1 and Check LFC
Find the modular Jack-to-Jack (J/J) cable supplied and connect one end to Telguard
Jack 1 and
other end to the RJ31X. Note that the
STC
LED goes out and the STC relay returns to normal due to
telco line restoral.
5.4.3 Connect STC Trip Output
Connect the STC trip output (terminals 1 & 2, N.O.) to the 24-hour zone input of C/C.
NOTE:
Activation of a local alarm or strobe light may be desirable when a trip is declared. The
STC trip output can be used directly to activate a local signaling device, provided that the trip
output is not needed to trip the host control/communicator at the same time. If both a local signal
and a control trip input is required, then external relays are needed to provide additional
uncommitted contacts.