User Manual

To Enter Disconnect Pulse Option
Press: # * 79 * <disconnect pulse> #
The disconnect pulse value is programmed in 1 millisecond increments from 10 to 65,535. A
value of 0 disables the disconnect pulse. If the value is not 0 or between 10 and 65,535, inclu-
sive, it will be considered invalid and the FWT will not update or store this value; the currently
stored value will remain. The factory default is 0.
To Enter Dial Tone Frequency Selection Option
Press: # * 80 * <dial tone frequency> #
The dial tone frequency value is set to 0 to select the North American dial tone frequency pair
(350 + 440 Hz) ; set to 1 to select European dial tone frequency (425 Hz). If the dial tone fre-
quency selection option value is neither 0 nor 1, it is considered invalid and the FWT will not
update or store this value; the currently stored value will remain. The factory default is 0.
To Enter Mobile Equipment Personalization Option
Press: # * 37 * <MEP lock type> * <MEP Operation> * <MEP Password> #
The MEP lock type value is set to 0 for SIM personalization; 1 for Network personalization; 2 for
Network subset personalization, 3 for Service Provider personalization, 4 for Corporate person-
alization. If the MEP lock type value is not in the range 0 to 4, it is considered invalid. The MEP
operation value is set to 0 to activate personalization; 1 to deactivate personalization; 2 to dis-
able personalization; 3 is reserved for future use. If the MEP operation value is not in the range
0 to 3, it is considered invalid. The MEP password is a special value available only to authorized
personnel. Factory default is all lock types set to deactivated.
To Program the Operation and Maintenance Center Terminate Number
This is the number that the FWT receives calls from:
Press: # * 83 * < number> #
If the number length is greater than 16 numeric digits, it will be considered invalid. If no number
is entered, the stored value is null. The factory default is null.
Phonecell
®
SX5e GSM 21 Technical Manual