User's Manual
Call Alert Tone
The following key sequence is used to set the call alert tone:
Label: CALL ALERT TONE
Data: <tone number>
The tone value is set to 1 for medium tone, 2 for low tone, and 3 for high tone. If the tone num-
ber is not in the range of 1 to 3, it is considered invalid. The factory default is 1.
Auto Send Delay
The following key sequence is used to enter the auto send delay:
Label: AUTO SEND DELAY
Data: <delay>
If the delay is not in the range of 2 to 20 seconds, it is considered invalid. The factory default is 3.
RSSI Display Type Option
The following key sequence is used to select the RSSI display option:
Label: RSSI DISPLAY
Data: <type>
The type value is set to 0 for direct readout in dBm or 1 for bar graph. If the RSSI display type
value is greater than 1, it is considered invalid. The factory default is 1.
LCD Display Contrast
The following key sequence is used to enter the LCD Display Contrast:
Label: LCD CONTRAST
Data: <contrast>
If the LCD contrast is not in the range of 0 (darkest contrast) to 19 (lightest contrast), it is consid-
ered invalid. The factory default is 5.
Zero Delay Dial
The following key sequence is used to enter the Zero Delay Dial option:
Label: ZERO DELAY DIAL
Data: <zero delay dial>
The zero delay dial value is set to 0 for Disable and 1 for Enable. The factory default is 1
(Enable).
Mobile Identification Number (MIN)
The following key sequence is used to view the SX4P MIN (phone number):
Label: MIN: _________ _
This is a read-only feature and is not user programmable.
Phonecell SX4P TDMA 800 12 User Manual