Installation Instructions

RF Unit USER AND
INSTALLATION
MANUAL
Code: D168X01_DDS09
Date: 16/06/09 Page: 15 of 16
01.01.00/1 Rev.1
RTX P25
ON OFF
INTERNAL POWER SUPPLY FAILURE.
CONTACT TECHNICAL SERVICES.
REF. ERROR
ON
Failure in the 10MHz reference. Contact Technical
services.
INT. ERROR ON Internal failure. Contact Technical services.
BUS ERROR ON
Communication failure with the RCPU P25 module.
Check that all the modules are correctly installed.
Contact Technical services if still unsolved.
RPA P25
ERROR
ON
FAILURE IN THE RPA P25 MODULES. CHECK
THAT THE RF SMB CABLES (REF. 10) ARE
PROPERLY CONNECTED. CONTACT
TECHNICAL SERVICES IF STILL UNSOLVED.
RPW ERROR
ON
Reflected power alarm. Check that the antenna is
properly installed. Contact Technical services.
RRX P25
ON OFF
INTERNAL POWER SUPPLY FAILURE.
CONTACT TECHNICAL SERVICES.
REF. ERROR
ON
Failure in the 10MHz reference. Contact Technical
services.
INT. ERROR ON Internal failure. Contact Technical services.
BUS ERROR ON
Communication failure with the RCPU P25 module.
Check that all the modules are correctly installed.
Contact Technical Services if still unsolved.
BSYNC
ON OFF
INTERNAL POWER SUPPLY FAILURE.
CONTACT TECHNICAL SERVICES.
REF. ERROR
ON
Failure in the 10MHz reference. Contact Technical
services.
TIME GPS ON
If GPS is activated, there is failure in the data frame.
Contact Technical Services.
PPS GPS OFF
If GPS is activated, there is failure in the PPS signal of
the GPS:
- check that the starting up period has been exceeded
(about 10 minutes after switching on)
- check the GPS antenna connection.
- check the correct positioning of the GPS antenna, in
accordance with the manufacturer’s instructions.
Contact technical services if still unsolved.
TIME LOCAL OFF
If GPS is not activated, there is failure in the local
reference data frame. Contact Technical Services.
PPS LOCAL OFF
If GPS is not activated, there is failure in the local PPS