Installation Instructions
RF Unit USER AND
INSTALLATION
MANUAL
Code: D168X01_DDS09
Date: 16/06/09 Page: 14 of 16
01.01.00/1 Rev.1
7. CONFIGURATION
A RF Unit is configured via an NMS (Network Management System). To configure
the RF Unit, consult the NMS manual.
8. INCIDENTS
The repeater must be repaired by authorized technical personnel only. If a RF
Unit failure occurs, the entire RF Unit must be replaced. If transmitter module
is damaged and there is not an entire RF Unit available to replace, set RTX
P25 and RPA P25 modules previously calibrated jointly. In last case and if is
not possible to carry out one of the two previous options, replace one of these two
modules and make the gain calibration again.
If an error or alarm occurs in the RF Unit, this is indicated in the corresponding
LED for each one of the modules. The following list shows the possible failures and their
solutions.
8.1.
ALARMS
Led
indication
Status
Failure / Solution
RPS
SUPPLY OFF
POWER SUPPLY FAILURE. CHECK THAT THE
SOURCE AND THE POWER SUPPLY CABLE
ARE CORRECTLY CONNECTED. CHECK THE
INTERNAL FUSE OF THE RPS. CONTACT
TECHNICAL SERVICES IF UNSOLVED.
26.4V OFF Power supply failure. Contact Technical services.
13.2V OFF Power supply failure. Contact Technical services.
RPA P25
ON OFF
POWER SUPPLY FAILURE. CONTACT
TECHNICAL SERVICES.
TX POWER OFF
No power transmission in the antenna. Wait for RF Unit
to be started up. Check other LED indications. Contact
Technical Services if unsolved.
!