User's Manual

Code: D148X01PT_DDS06
MBS USER AND
INSTALLATION
MANUAL
Date: 19-Dec-2012 Page: 31 of 36
01.01.00/1 Rev.1
Ensure that the connection is made in the correct way (Positive, Negative
and Earth) following the next steps:
Strip cable and wires (stripping length 8 mm - 9 mm).
NOTE: The Earth cable must be 2 mm longer.
Push the cable through the cable gland and the hood/housing and
insert the wires into the insert respecting the correct polarity.
Fix each wire tightening each pin from the front side with a hexagonal
screwdriver (Allen number 2).
Push the insert back into the hood/housing.
8-9mm
Negative (-)
Positive
(+)
Earth (PE)