q In installations with diversity, the greatest gain is achieved by placing the
antennas on the same horizontal plane with a minimum distance of 5.5 m
between them.
q Measure the ROE of the installation. Never accept a ROE greater than 2.
6.3.4.4. EXTERNAL ETHERNET CONNECTION
q The Ethernet cable connector, to connect the MBS Unit with the radio link
(PoE), is supplied with every MBS Unit.
Note: In the case of connection to two radio links, it is recommended to
contact your supplier and/or installer who will provide the additional Ethernet
cable connector.
q The Ethernet wire for the radio link connections is supplied by the installer,
and must have the following characteristics:
§ Cable with 8 wires, FTP cat5E with outdoor protection.
§ Diameter: 6.5 mm to 9.5 mm.
§ Maximum length: 100 m
§ Mount the wire on the connector according to the TIA / EIA 568B
standard (The assembly requires no tools, is done manually).
Pin
Color T568B
Pins on plug face (socket is reversed)
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown)
8
Brown