6.3.4.2. CONNECTION OF THE EXTERNAL POWER SUPPLY
Check that the power supply source and/or the battery to be used are
adapted to the type of MBS Unit (AC/DC) and meets the voltage and current
requirements necessary to supply the equipment.
a) MBS Unit with AC power supply source:
q Nominal voltage: 110/220 VAC (Range: from 94 to 264 VAC).
q Use the power cable connector provided with the MBS Unit to connect the
MBS Unit to the power supply source. Use a cable of 3 wires; with weather
protection; with the following features:
§ Cable diameter: 6 mm - 12 mm.
§ Cable section: 4 mm² (0.6/1KV) or AWG-11.
q Ensure that the connection is made in the correct way (Line, Neutral and
Earth) following the next steps:
§ Strip cable and wires (stripping length 8 mm -9 mm).
NOTE: The earth cable must be 2 mm longer.
§ Push the cable through the cable gland and the hood/housing and
insert the wires into the insert respecting the correct polarity.
8-9mm
Neutral (N)
Line (L)