9 SPECIAL FUNCTIONS
9.1 Emergency calls
By keeping key pressed, an emergency call is begun, which has maximum
priority and will cancel any call being made at that moment.
This type of call can be configured by programming, and can be: private semi-duplex direct
call, group call, broadcast call, telephone call (PSTN, PABX) or status message.
It is also possible to configure the emergency call in DMO, being able to configure a different
call destination in V+D and DMO.
The emergency icon will be displayed flashing on the display.
If the equipment cannot establish the call or send the status message, it will continue trying,
unless the user cancels the call by pressing the emergency key again.
After a loss of service or equipment being switched off, the emergency call will try to be re-
established when the equipment is operational again if the parameter “Continue emergency
call” is enabled by programming.
If the emergency call is a voice call, there is an initial automatic transmission time (5 seconds
by default) for semi-duplex calls, without having to press PTT.
When this time is over, the user must press PTT to transmit as usual (if it is a semi-duplex
call).
This type of call can also be initiated by activating an external input (available in the rear
connector) to which, for example, an emergency pressure pad can be connected. Consult your
Service Provider about the availability of this option.