System Manual

BreezeCOMPACT System Manual
74
Chapter 3: Operation and Administration
Procedures
BreezeCOMPACT Full Configuration via CLI
set networking external-management use-bearer-ip-address false
To show the current configuration:
At the Breezecompact% prompt , enter the following command:
17
show networking external-management use-bearer-ip-address As a result you will see the
following output:
use-bearer-ip-address false;
3.3.2.7
Data Port redundancy
To make BreezeCOMPACT1000/3000 DAT1 and DAT2 redundancy the DAT1 (fiber) and DAT2
(copper) links must be active in the same time.
Only one port will be active a time (preferred is DAT1) and in time connection (link) failed, the
eNB will be switch its connectivity to DAT2.
Note: In R6.9, BreezeCOMPACT with embedded EPC hardware (1000e) does not support
dynamic data port redundancy. For further information, please contact Telrad CS.
3.3.2.8
Modifying Physical Data Port Parameters
Modifying physical data port parameters is optional.
A 1GB interface can use either the DAT1 (Fiber) or DAT2 (Copper) interface.