System Manual

BreezeCOMPACT System Manual
51
Chapter 2: Commissioning Steps
BreezeCOMPACT Co
mmissioning
2.1.3.2
eNodeB initial general and external management parameters
This section describes how to define the management parameters for the CLI and the
BreezeVIEW connectivity. To define CLI with BreezeVIEW - general and external
Management connection parameters:
1
Perform the procedure described in Section 2.1.3.1, Initial Out-of-the-Box Connection.
2
Perform eNodeB Timing and GPS configuration as described in Section 4.2.2.11
3
Perform basic device commissioning procedure
Set Device ID
At the B
BreezeCompact%
prompt, set parameters by entering the following
commands: set device general device-id < unsignedInt, 1 .. 999999 >
For embedded eNB (BreezeCompact 1000e) use the following command to
enable/disable EPC
set device general enable-embedded-EPC
<Disable or Enable>.
External management IP parameters
At the B
BreezeCompact%
prompt, set parameters by entering the following
commands:
set networking external-management ip-address
<The external management IP
address >
set networking external-management subnet-mask
<The external management
subnet mask >
set networking external-management next-hop-gateway
<The external
management default gateway>
set networking external-management vlan-id
<VLAN of the external
management >
This value can be a vlan number or NoVLAN in case that this external
management port is not tagged with VLAN.
set networking external-management use-bearer-ip-address
<true or false >
The default value is false. Set the value to true in case that the s1 bearer address
and the external management will have the same IP address