System Manual

BreezeCOMPACT System Manual
118
Chapter 3: Operation and Administration
Procedures
Spectrum
Analyzer
Each frequency scanned (one row) is comprised of multiple Resource Blocks (RBs) within the
bandwidth used. In most cases Median/Min/Max NI measurement will give good indication for
interference.
Explanation about the table fields:
Table 3-2: SA results table
Measurement
Description
Units
ANTENNA PORT
BreezeCOMPACT port number
1,2,3,4
FREQUENCY
RF Central frequency
kHz
MEDIAN NI
Median NI
dBm
MIN ENERGY
Minimum NI
dBm
MAX ENERGY
Maximum NI
dBm
FREQUENCY OF
MAX RB
Frequency of Maximum NI
kHz
RB INDEX AT MAX
ENERGY
Telrad internal use
1
96
RMS PER RB
RMS normalize for 1RB
dBm
RMS ALL RBS
RMS of the BW
dBm
SCANNING Time
Time of the latest result of the measurements at specific
RF frequency
KEY RB RESULTS
Numbers in order according to the number of the RBs
(Recourse Blocks)
1 …. 100
RB RESULT
Energy per RB
dBm