System Manual
BreezeCOMPACT System Manual
116
Chapter 3: Operation and Administration
Procedures
Spectrum Analyzer
state scanning-state options:
Disable (spectrum analyzer is not in active scanning), Enable (spectrum analyzer is in active
scanning)
3.10.2.2
Spectrum analyzer configuration
The default spectrum analyzers settings can be used, the frequency scanning range will be
defined as the whole band supported by the BreezeCompact hardware, however in order to
minimize the scanning time it is recommend to perform scanning on the desired spectrum.
Use “show” command to display the Spectrum Analyzer scanning parameters. For example:
BreezeCompact% show spectrum-analyzer scanning
start-frequency 3400000;
stop-frequency 3700000;
frequency-step 1000;
interval 1000;
repetitions 0;
Configurable parameters:
start-frequency – Scanning start frequency (in kHz) stop-frequency – Scanning
stop frequency (in kHz)
frequency-step – Scanning step/resolution frequency (in kHz), minimum step of
0kHz step, default 1000kHz
interval – defines the time to between each frequency steps, higher interval time
will enable more measurements but increase the overall scanning duration,
minimum internal 10msec, default 1 second.
repetitions – in cases where operator would like to perform several scans for a
period of time, it can define the repetition number. For example repetition value
1, the spectrum analyzer will scan the frequency range two rounds. In default
case (0), only one round of spectrum scan will be reported.
Use “set” command for configuration of the above parameters:
BreezeCompact% set spectrum-analyzer scanning <Parameter> <Value> Perform commit
command:
BreezeCompact% commit
Use command “show spectrum-analyzer scanning” to verify definitions
BreezeCompact% show spectrum-analyzer scanning
start-frequency 3480000;
stop-frequency 3530000;
frequency-step 1000;