BreezeCOMPACT System Manual
Chapter 3 - Operation and AdministrationGPS Menu
Chapter 3 - Operation and Administration GPS Menu
85
3.9.1.6 Time Zone Offset From UTC
The offset of the local time from the UTC.
The range is -12:00 to +13:00 in 30 minutes resolution. The default is +00.00.
3.9.1.7 Local Time and Date
A read-only display of the local date and time (using 24-hour clock) as calculated using the UTC Time
and Date and taking into account the Time Zone Offset From UTC and Daylight Saving Time parameters.
The format is: hh:mm:ss; dd/mm/yyyy.
3.9.1.8 Daylight Saving Mode
The Daylight Saving Mode parameter is used to enable or disable the daylight saving feature using the
following Start Date, Stop Date and Advance Hour Factor parameters. The default is Disable.
A change in Daylight Saving Mode will take effect after next reset.
3.9.1.9 Advance Hour Factor
When Daylight Saving is enabled, this parameter defines the amount of time by which the clock should
be advanced during the daylight saving period.
The available values are 0 (daylight saving disabled), 1 and 2 (hours). The default is 0.
3.9.1.10 Start Date
When Daylight Saving is enabled, this parameter defines the date for starting the daylight saving
feature. At the beginning of this date (midnight at the beginning of this date), the clock will be
advanced by the amount of hours specified by the Advance Hour Factor.
Use the format dd.mm to define the date and month at which to start activating the Daylight Saving
feature.
A change in Start Date will take effect after next reset.
3.9.1.11 Stop Date
When Daylight Saving is enabled, this parameter defines the date for ending the daylight saving feature
(at “Advance Hour Factor” hours after midnight at the end of this date).
Use the format dd.mm to define the date and month at which to end activating the Daylight Saving
feature.
A change in Stop Date will take effect after next reset.
3.9.1.12 External 1PPS
Indicates whether the external 1PPS clock is enabled or disabled.