User Manual
Table Of Contents
- System Manual
- BreezeCOMPACT
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - System Description
- Chapter 2 - Commissioning
- 2.1 Introduction
- 2.2 BreezeCOMPACT Installation
- 2.3 System Initial Verification
- 2.4 Configuring Parameters Required for Management Connectivity
- 2.4.1 Configuring the BTS Number
- 2.4.2 Configuring the Management Interface Connectivity Mode Parameter
- 2.4.3 Configuring the IP Interfaces Parameters
- 2.4.4 Configuring the L1 and L2 Parameters (if necessary)
- 2.4.5 Configuring the SNMP Authorized Manager and Traps Manager
- 2.4.6 Applying the Configuration
- 2.5 Activating the Unit
- Chapter 3 - Operation and Administration
BreezeCOMPACT System Manual
Chapter 3 - Operation and AdministrationRH Menu
Chapter 3 - Operation and Administration RH Menu
89
3.10.1.1 External Cavity Filter Existence
Informational parameter indicating whether an external cavity filter exists (true/false). The default is false
(external filter does not exist).
3.10.2 Ports
The RH Ports menu enables viewing the general port status parameters for all ports or for a selected
radio ports:
3.10.2.1 Calculated TX Power
The required Tx power at the radio port, in dBm. Calculated according to the Tx Power configured for
the Radio Cluster and the Topology Type. In the current release (supporting only One Sector One Carrier
topology) the RH Port Calculated Tx Power equals the Radio Cluster’s Tx Power.
3.10.2.2 RH Status Mask
Read-only. A decimal number representing the value of a 32-bits mask (bits 0-31) indicating possible
failures. Applicable only for an installed and associated RH. For a No Failure status the value is 0. If the
value is other than 0 contact Customer Support.