Installation and Operation Instructions

Telrad Networks Ltd. BreezeAIR Installation Guide
Page 17 of 29
2
2
.
.
3
3
.
.
6
6
C
C
a
a
b
b
l
l
e
e
s
s
The outdoor unit is connected to straight CAT5 Gauge 24-shielded outdoor rated cable. The
cable should be UV resistant, flame retardant, UL listed and contain at least 4 twisted
pairs.
The outdoor cables scheme is indicated in Appendix A Outdoor Cables Scheme.
The Indoor PoE Outlet side and Outdoor Unit side are crimped using RJ-45 tool.

Total length of the CAT5 cables must not exceed 100 meters

The Outdoor Unit side is assembled according to the following steps (figure 2-5):
Insert sealing nut on the cable.
Insert claw and rubber seal on the cable.
Crimp the RJ-45 Plug.
Figure 2-5: Cable preparation for Outdoor Unit
Insert the RJ-45 to the Outdoor Unit (Figure 2-6).
Fasten the seal nut to the gland Body
The unused port should be left sealed.
Figure 2-6: Cable connection to Outdoor Unit