User's Manual

High Voltage Installation (Non-Class 2)
EcoInsight+ SS6010
I, O & M Guide
Telkonet, Inc.
For Use with Firmware Version 2.x
20800 Swenson Drive, Suite 175
High Voltage Installation (Non-Class 2)
Waukesha, WI 53186
Revision 2.1
(800) 380-9640
Page 14
www.telkonet.com
OUTPUTS (+):
Position
Relay
Terminal
Ratings
Current / power Voltage Load type Action Type Design
RLY1,
RLY2,
RLY3
RLY1:J3-1 (R)
and
J3-3 (AUX)
RLY2:J3-5
(W1/Y1)
and
J3-4 (W1)
RLY3:J3-5
(W1/Y1)
and
J3-6 (Y1)
See note 1
5A
125/250/277
VAC
General use
Operating
1.C
RLY5,
RYL7
RLY5: J3-9
(G/O/W2) and
J3-7 (G)
See Note 3
RLY7: J3-9
(G/O/W2)
and
J3-8 (O)
See Note 3
See Note 1
10A 125 VAC General use
Operating
1.C
8A 277 VAC General use
1/10HP 125 VAC Motor
1/6HP
250 VAC &
277 VAC
Motor
RLY8
J3-9
(G/O/W2)
and
J3-10 (W2)
See Note 3
See Note 1
16A 277 VAC
Resistive (including
Fixed Electric Space
Heating) See Note 2
Operating
1.A.Y
See Note 2
1HP 250 VAC Motor
1HP 277 VAC Motor
½HP 125 VAC Motor
Note 1: J3-1 (R), J3-5 (W1/Y1), and J3-9 (G/O/W2) – must be connected to the same pole of the same supply
circuit. Relay contacts must be connected in a same polarity fashion.
Note 2: Relay RLY8 is the only output device rated for the control of fixed electric space heating
equipment. This relay will de-energize when the On/Off switch is adjusted to the “OFF” position. RLY8 only