User's Manual

Table Of Contents
BlueMod+S42 Hardware User Guide
1VV0301303 Rev.32016-08-22
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.
Page 39 of 62
5.4.2 EXT-RES#
Input EXT-RES# has a Schmitt-Trigger characteristic and an internal pull-up resistor.
T
amb
= 25°C
Symbol Item Condition Limit Unit
Min Typ Max
V
IL
Low-Level Threshold VSUP = 1,7 to 3,6V 0,34*VSUP V
V
IH
High-Level Threshold VSUP = 1,7 to 3,6V 0,62*VSUP V
V
HYST
Hysteresis VSUP = 3,0V 800 mV
R
PU
pull-up resistor 11 13 16 kΩ
C
l
Input Capacitance 2,5 pF
Table 13: DC Characteristics, EXT-RES#