5.4.1 SPP configuration
5.4.1.1 Deep Sleep state
The Bluetooth RF is completely deactivated; no paging requests from other Blu-
etooth devices will be recognized. Only rising control line DTR will activate the Blu-
eMod+C11/G2 and may initiate a Bluetooth link dependent on other parameters.
Note: In Deep Sleep state the AT command set is not active, CTS line is low
5.4.1.2 Power down state
The Bluetooth RF is activated every 1.25 seconds, paging requests from other Blu-
etooth devices will be recognized after that intervals and accepted if allowed. Addi-
tionally rising control line DTR will activate the BlueMod+C11/G2 and may initiate a
Bluetooth link dependent on other parameters.
Note: In Power down state the AT command set is not active, CTS line is low
5.4.1.3 Idle state
The Bluetooth RF is activated every 1.25 seconds, paging requests from other Blu-
etooth devices will be recognized after that intervals and accepted if allowed. Addi-
tionally rising control line DTR will activate the BlueMod+C11/G2 and may initiate a
Bluetooth link dependent on other parameters
5.4.1.4 Power Consumption
Vcc = 3.3V, T
amb
= 20°C
Condition
Current Consump-
tion
Unit
I
MEAN
I
PEAK
RESET
28,3
28,3
mA
Deep sleep
3,41
11
mA
Power down
7,1
57,7
mA
Idle, all functions available, no Bluetooth link
8
62
mA
Page Scan
12,1
101,0
mA
Inquiry and Page Scan
12,4
101,0
mA
Bluetooth connected, no data traffic, max. TX PWR
(Slave)
34,7
185,0
mA
ACL connected DH5 max PWR, shortest Poll Period
(Slave)
133,3
175,0
mA
ACL connected DH5 min PWR, shortest Poll Period
(Slave)
57,5
99,0
mA
ACL connected DH1 max PWR, shortest Poll Period
(Slave)
59,0
175,0
mA
ACL connected DH1 min PWR, shortest Poll Period
(Slave)
55,0
110,0
mA