User's Manual

BlueMod+C11/G2
Hardware Reference
www.stollmann.de Page 18 of 42
5 Electrical Characteristics
5.1 Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause per-
manent damage to the device. These are stress ratings only, and functional opera-
tion of the device at these or any other conditions beyond those indicated under
“Electrical Requirements” is not implied. Exposure to absolute-maximum-rated con-
ditions for extended periods may affect device reliability.
Item
Symbol
Absolute Maximum Ratings
Unit
Supply voltage
V
cc
3,7V with respect to GND to
- 0,4V with respect to GND
V
Voltage on any pin
V
Pin
VCC + 0,4V with respect to GND to
- 0,4V with respect to GND
V
Input RF level
P
max
0
dBm
ESD on any pin
V
ESD
This device is ESD sensitive. Handling and
assembly of this device should be at ESD pro-
tected workstations.
5.2 Environmental Requirements
Item
Symbol
Absolute Maximum Ratings
Unit
Storage temperature range
T
stg
-40 to +105
°C
Operating temperature range
T
op
-40 to +85
°C