User Instructions
Stollmann
E + V GmbH
BlueRS+I
DesignGuide
Author: cl Date of Savin
g
: 19.03.04 Ref: Revision: 1.2 Pa
g
e 16 of 22
5.6.3 Idle state
No power down mode activated.w
All functionality is available immediately including connection control using AT
command set.
5.6.4 Power consumption
The following values are approximate power consumption values in the different
states:
Condition Current Consumption
(3.3V or 5V DC)
Deep sleep ~ 0.7 mA
Power down ~ 2.5 mA
Idle, all functions available, no Bluetooth link ~ 22 mA
Bluetooth connected, no data traffic,
(Master/slave)
~ 24 / 35 mA
Bluetooth connected, data traffic 115 kbit/s ~ 46 mA
5.6.5 Power-up time
The time until the BlueRS+I is able to accept link requests or serial data is about 9
seconds after power-up.