User's Manual
1.07work/09.2003 BlueRS+ manual
4. BlueRS+C2 Configurator command set
© Stollmann Entwicklungs- und Vertriebs-GmbH 27
4.4 List of BlueRS+C2Configurator commands
The BlueRS+C2Configurator commands typed in must have the correct syntax and
be complete, including all blanks. Capital/small letter use is not important. The entry
is not case sensitive.
The bolded values are factory defaults. The usage is:
[?]<command>[=parameter]
Example to set the baudrate to 9600 baud:
br=4
Example to show the selected baudrate:
br
Example to show all selectable baudrates:
?br
To get an overview about the commands of your BlueRS+C2 some major commands
here as a preview:
show show the usually used parameter
showall show all changeable parameter
quit leave BlueRS+C2Configurator
help show all available commands
defa 1 setup factory default parameter set
save store parameter non volatile
at.sx AT command parameter set
AT command set only:
Handle AT specific settings.
Show and change AT S registers by entering the new value.
at.s0 show setting of S0-Register
at.s0=1 set Register S0 to 1
boad Bluetooth Device Own Address
With this command you can read out the own Bluetooth device address.
(read only)
Example:
boad
bpin Bluetooth device Pin (Passkey)