© Stollmann Entwicklungs- und Vertriebs-GmbH 13
AT&K5 Local flow control is set to hardware handshake RTS/CTS
additionally in AT command phase
O Return to online state
If the BlueRS+C2 is in command mode after issuing an escape sequence out of an
existing connection, ATO brings the BlueRS+C2 back to data phase.
Must be the last command in AT command line.
ATO
Q Suppress results
With this command result codes or messages can be suppressed.
ATQ Returns status - codes after command input (default)
ATQ1 No result codes are returned
&R CTS control
Selects the behavior of the CTS control line from the BlueRS+C2.
AT&R BlueRS+C2 control line CTS is following all changes of RTS
AT&R1 CTS is always ON (default)
AT&R2 BlueRS+C2 control line CTS is following all changes of DTR
AT&R3 BlueRS+C2 control line CTS is following all changes of remote
CTS (set for cable replacement)
S Display and set internal S register
ATSnn? Show actual values (decimal) of selected register nn
ATSnn=xxx Set selected register nn to the decimal value xxx.
See S register definitions on page 21.
&S DSR control
Selects the behavior of the DSR control line from the BlueRS+C2.
AT&S BlueRS+C2 control line DSR is always ON (default)
AT&S1 DSR ON indicates Bluetooth link is established
AT&S2 BlueRS+C2 control line DSR is following all changes of DTR
AT&S3 BlueRS+C2 control line DSR is following all changes of DCD
AT&S4 BlueRS+C2 control line DSR is following all changes of remote
DSR (set for cable replacement)
AT&S5 reserved