User's Manual
BlueRS+ manual 1.07work/09.2003
3. Using the BlueRS+C2
10 © Stollmann Entwicklungs- und Vertriebs-GmbH
By using initialization strings to configure the TA which includes more than one
parameter to be configured please follow the examples below:
• Initialization string includes standard AT commands:
AT&F&D2&C1E0&W
By using a special configuration command (at**<cmd>) in the initialization string you
have to set a semicolon <;> in case that additional commands will follow.
• Initialization string includes special AT commands:
AT&F**BR=8;&D2&C1E0&W
Supported commands:
A/ Repeat last command line
This command repeats the commands of the last entered command line.
Note: No prefix AT is required.
A/
A Accept incoming call
Using this command you can accept an incoming call, if automatic call acceptance is
not set (Register S0 = 0). An incoming call is always displayed by the message
“RING“ or the code “2“, also if automatic call acceptance is selected.
Must be the last command in an AT command line.
CONF Enter BlueRS+C2Configurator
Enters directly into the BlueRS+C2Configurator, the configuration prompt "#" will be
displayed. Leave the BlueRS+C2Configurator with the command "quit" (or “exit” or
“go”).
ATCONF
&C DCD control
Selects the behavior of the DCD control line from the BlueRS+C2.
AT&C BlueRS+C2 control line DCD is always ON
AT&C1 DCD ON indicates Bluetooth connection is established (default)
AT&C2 DCD line follows DTR
AT&C4 DCD follows remote DCD
D Initiate Bluetooth link