WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 22 of 48
4.3.2 Manual reset
An active low manual reset (MR_RESET*, ball C1), see the table below for the allowed voltage levels.
As the pin is internally pulled-up, do not drive the signal during normal operation.
The signal must be asserted for a period greater than 1ms.
VOLTAGE LEVELS @ 25 °C
Min [V] Max [V] Remark
VIL -0,3 0,825
Table 10
Figure 8
WE865-DUAL
MR_RESET*